On Mon, Dec 22, 2008 at 4:15 PM, Dale Worley <dwor...@nortel.com> wrote:
> On Mon, 2008-12-22 at 22:05 +0100, erik.lars...@tieto.com wrote:
>> I am planning to use 3PCC and the B2BUA in the coming 4.0 release
>> sounds promising. What interfaces are provided here?
>
> You might want to look into RFC 3725.
>
> Dale
>


Actually the B2BUA in 4.0 will not provide a programming interface. It
is specialized as a session border controller (SBC) for interfacing to
IP Telephony service providers ( ITSP ). It will be the default SBC
bundled with sipxbridge for interfacing with ITSPs.

If you wanted to program up a stand alone B2BUA for 3PCC and do not
wish to (or cannot) use the REFER method to effect the transfer, you
can look at 3275 and use one of several fine free sip stacks to build
what you want.

Ranga


>
> _______________________________________________
> sipx-users mailing list
> sipx-users@list.sipfoundry.org
> List Archive: http://list.sipfoundry.org/archive/sipx-users
> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
>



-- 
M. Ranganathan
_______________________________________________
sipx-users mailing list
sipx-users@list.sipfoundry.org
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users

Reply via email to