Hi all,

had a disaster of a day here, been trying to install a Samsung Ubigate 
gateway onto a Siemens switch in order to get my Sip-X installation up and 
running.  Basically, the gateway is in place and speaking to the TDM 
switch, and traffic passes happily between them.  Outgoing calls are fine, 
no problem at all.  Inbound calls however, ring the phone momentarily and 
then cut off, while the caller hears the classic 'that extension is not 
valid'.  Both the phone and gateway get a cancel message from the Sip-X 
box.  The extensions are defined as normal in Sip-X, the phones are 
registered, the message gets there and then is just as quickly cancelled. 
Infuriating!

I figure it's a dial plan issue, but I cant think what.  It worked 
perfectly for my analogue gateway, but not now with my digital one.  I'm 
not thinking straight after 8 hours on the job with no food or water, so 
I'll try and fix it tomorrow.  I'm using version 3.10 from the build disk, 
anyone had this issue before?

Kenny Mitchell
INEOS Refinery
Grangemouth