On Thu, 2009-12-03 at 12:55 +0800, Michael Perez wrote: > Good day, > > I am having a problem with my ITSP at the moment, we are still trying to > identify the error, when I point the calls at 5060, the calls seems to > go through, but no audio is available both end. But when I have them > point the signalling back to me at 5080, I receive 500, Internal Server > Error. ITSP site is using Cisco-SIPGateway/IOS-12.x and Centrex for Call > Control. > > I tried with another ITSP which using Sansay, after some test and > adjustment on my end, it was successful. > > I am attaching a PCAP file that shows the failure call and the sample > successful call for your comment. Hope someone can help me fix this.
There's a posting size limit (60K) on the list. A 500 response indicates an internal error in the sipXbridge - look in /var/log/sipxpbx/sipxbridge.log and you should find something that further indicates what the problem was. Set the log level at INFO (System->General->Logging). _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/