> -----Original Message----- > From: Tony Graziano [mailto:tgrazi...@myitdepartment.net] > Sent: Wednesday, March 03, 2010 4:16 PM > To: Joly, Robert AVAYA (CAR:9D30) > Cc: Sipx-dev list; Sipx-users list > Subject: Re: [sipX-dev] sipxbridge and remote users without > server behind nat > > > > On Wed, Mar 3, 2010 at 4:01 PM, Robert Joly <rj...@avaya.com> wrote: > > > > Does sipxbridge have to be behind nat in order for remote > > users or trunking to work? > > > Yes as long as you uncheck the 'Server behind NAT' > checkbox under > System->Internet Calling->NAT Traversal. BTW, just to > make sure, > sipXbridge and remote NAT traversal are two different > beasts - please > see questions #1 and #2 of the FAQ section at the bottom of > > http://wiki.sipfoundry.org/display/xecsuserV4r0/Remote+User+NA > T+Traversa > l. > > 8< > > > > That was unchecked already. > > Remote User = Yes > Server behind NAT = No > > All standard settings (static IP, not STUN), calls sent to port 5080.
Are the phones also pointed at port 5080? 5080 is the port to be used by ITSPs. All users, local or remote, must connect to port 5060. > > ITSP is from the template and setup just like my others with > the same ITSP. > > User registers. Can call the AA,but not VM (no audio, the > call connects). User can call out and be called. > > Has anyone ever done this before? I had a close variant of that, but not that setup exactly. _______________________________________________ sipx-users mailing list sipx-users@list.sipfoundry.org List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/