Hi,

I have a Sipxecs box with one interface having a public IP address (213...) and 
one having a local address (192.168.1.)
How do I configure this, I can only tell it that it has one IP address. 
I Configured the Local address as Primary IP Address,
The Public IP Address has been specified with NAT (although NAT has been 
disabled).

This internal phones (Gigaset, Dect) do register and can call each other 
through the internal interface.
Operator, Voicemail, and routing to a SIP gateway don't work and terminate with 
408 immediately.

Of all the services only sipxacd (tcp & udp, 5150&5152) & freeswitch (udp& tcp 
15060) listen on the public interface
sipxacd also listens on the pivate address on 5150&5152 and for 8110 in general 
,
 freeswitch listens on lo: tcp 8021 and private tcp 8080.

So how how should this be configured. (BTW there is a ton of information about 
how to configure sipxecs on one interface internally
but that is hardly an option with all the ALG's sitting in the way.,
It has been on the LAN but that caused a lot of problems as well, depending on 
make & model.
(Boy do i hate NAT, Glad IPv6 will be needed sooon.)

kind regards,
Nico