PSTN <--PRI--> sipx-branch1 <--ISP-->

                                                 ||

                                         VPN Tunnel

                                                 ||

                                          sipxbranch2

it should just be a gateway just like the existing one. the only questions
would be adjusting the ACL to allow that IP network to use it and the
mediant dial plan to handle the other sipdomain equally, and what numbers to
point to which sipx server for DID.

On Sun, Sep 11, 2011 at 5:28 PM, m...@grounded.net <m...@grounded.net>wrote:

> On Sun, 11 Sep 2011 13:54:11 -0400, Tony Graziano wrote:
> > either make the remote branch remote users or connect the two sites via
> vpn
> > and add the new branch sipx server as acl ti the medians and use it as a
> > gateway.
>
> Thanks very much for the input. I have a better idea of what I am after
> now.
>
>
> > On Sep 11, 2011 1:34 PM, "m...@grounded.net" <m...@grounded.net> wrote:
> >>> without explaining what you have now in a way other than "a really good
> >>> LD
> >>> deal".
> >>>
> >> LD meaning that with our PRI services, we get a good long distance deal.
> >> If possible, I'd like to use our current trunks to provide 4 lines to a
> >> remote sipx server.
> >>
> >>> How about stating how your existing gateway or trunk is implemented? Is
> >>> it
> >>> a PRI? Is it a trunk? Is there a VPN between the two locations?
> >>>
> >> I was asking about sipx itself but see how that comes into the picture.
> >>
> >> The remote location is a small office that will need 4 trunks.
> >> If we had to, we would put a gateway there to convert analog phone lines
> >> to SIP trunks for sipx. That however adds to the cost.
> >>
> >> At the main location, we use the mediant 2000 to provide PRI/SIP trunks
> >> to our local sipx servers.
> >>
> >> One option could be allowing the remote server to get it's trunks
> >> directly off of the mediant.
> >> Another would be to use a virtual trunk provider to get trunks into the
> >> remote.
> >>
> >> My question however, was if I could use one sipx server (at our main
> >> location) to provide the 4 trunks needed to the remote sipx server.
> >>
> >>> Without using a PRI as the gateway or having both of the servers using
> >>> the
> >>> same sipdomain, it a lot more problematic from both a security and
> >>> permissions standpoint. It also depends on the capabilities on the ISTP
> >>> "if" it is a trunk.
> >>>
> >> We would manage the remote so it could be in the same domain. I would
> >> control both LAN's so could just allow the remote and local servers to
> >> communicate via firewall rule.
> >>
> >> Mike
> >>
> >>
> >>> On Sat, Sep 10, 2011 at 1:56 PM, m...@grounded.net <m...@grounded.net>
> >>> wrote:
> >>>
> >>>> Sorry if I've posted this multiple times, had some mailer problems and
> >>>> don't see it in the list so am reposting.
> >>>>
> >>>
> >>>> ---
> >>>>
> >>> I have to install a small system at a remote location. The system will
> >>> only
> >>> have about 4 trucks so makes no sense to order lines/gateway etc.
> >>> What I was wondering about is either getting SIP trunks from a provider
> >>> or,
> >>> getting them from my main sipx box?
> >>>
> >>> I have never delved into anything like this and wondering if it is
> >>> possible
> >>> to extend trunks over to a second (or more?) sipx servers.
> >>> Should I be looking at Branches?
> >>>
> >>> The reason I would do this is because we have a good LD deal so want to
> >>> take advantage of that rather than having to buy trunks.
> >>>
> >>>
> >>> Thanks.
> >>>
> >>> Mike
> >>>
> >>>
> >>> _______________________________________________
> >>> sipx-users mailing list
> >>> sipx-users@list.sipfoundry.org
> >>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
> >>>
> >>>
> >>> --
> >>> ======================
> >>> Tony Graziano, Manager
> >>> Telephone: 434.984.8430
> >>> sip: tgrazi...@voice.myitdepartment.net
> >>>
> >>> Fax: 434.465.6833
> >>>
> >>> Email: tgrazi...@myitdepartment.net
> >>>
> >>> LAN/Telephony/Security and Control Systems Helpdesk:
> >>> Telephone: 434.984.8426
> >>> sip: helpd...@voice.myitdepartment.net
> >>>
> >>> Helpdesk Contract Customers:
> >>> http://support.myitdepartment.net
> >>>
> >>> Blog:
> >>>
> >>> http://blog.myitdepartment.net
> >>>
> >>>
> >>> Linked-In Profile:
> http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4
> >>>
> >>>
> >>> Ask about our Internet faxservices!
> >> _______________________________________________
> >> sipx-users mailing list
> >> sipx-users@list.sipfoundry.org
> >> List Archive: http://list.sipfoundry.org/archive/sipx-users/
> _______________________________________________
> sipx-users mailing list
> sipx-users@list.sipfoundry.org
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>



-- 
======================
Tony Graziano, Manager
Telephone: 434.984.8430
sip: tgrazi...@voice.myitdepartment.net
Fax: 434.465.6833

Email: tgrazi...@myitdepartment.net

LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: helpd...@voice.myitdepartment.net

Helpdesk Contract Customers:
http://support.myitdepartment.net

<http://support.myitdepartment.net>Blog:
http://blog.myitdepartment.net

Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4

Ask about our Internet faxservices!
_______________________________________________
sipx-users mailing list
sipx-users@list.sipfoundry.org
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to