Ok so I downgraded to the 6.0 firmware and reconfigured the gateway... I'm still experiencing the same exact issue. For some reason its sending a 487 Request Terminated and when I go into the syslog I see this
[ERROR] SIPStackSession::HandleStackSetupEV failed because no remote IP The some call go through others don't. They all hit the gateway from the phones but are rejected... -- Jorge On Mar 20, 2012, at 5:12 PM, Robert Schroeder wrote: > Looks like you may need to register with them to create a login. There is > support maintenance that is needed on the device to download software. There > may be other options however I do not know of any other then the manufacturer. > > Rob > > From: sipx-users-boun...@list.sipfoundry.org > [mailto:sipx-users-boun...@list.sipfoundry.org] On Behalf Of Robert Schroeder > Sent: Tuesday, March 20, 2012 5:07 PM > To: sipx-users@list.sipfoundry.org > Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated > > Do you have an account with AudioCodes. You should be able to download from > them. > > Rob > > From: sipx-users-boun...@list.sipfoundry.org > [mailto:sipx-users-boun...@list.sipfoundry.org] On Behalf Of Jorge E. > Fernandez > Sent: Tuesday, March 20, 2012 5:00 PM > To: Discussion list for users of sipXecs software > Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated > > Where can I get version 6.0? > > -- > Jorge > > > > On Mar 20, 2012, at 4:14 PM, Mark Wood wrote: > > > Version 6.2.xxxxx has given us all kinds of problems. We always downgrade to > a 6.0 version > > Thanks, > Mark W. Wood > office: (760)202-0224 X2010 > Direct: (760)459-1981 > <image001.png> > www.redphonetech.com > > > > > From: Jorge E. Fernandez [mailto:jorge.fernan...@j9consultants.com] > Sent: Tuesday, March 20, 2012 12:53 PM > To: Discussion list for users of sipXecs software > Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated > > Im running an even higher version > > Version ID: 6.20.A022.003 > DSP Type: 0 > DSP Software Version: 62008 > DSP Software Name: 204IM > Flash Version: 199 > > -- > Jorge > > > > On Mar 20, 2012, at 3:49 PM, Robert Schroeder wrote: > > > > Just for information purposes. This is the device information for the > AudioCodes Mediant 1000 device that we are using with three PRI circuits on > trunk modules. > > Version ID: > 6.00A.032.003 > DSP Type: > 2 > DSP Software Version: > 60008 > DSP Software Name: > 624AE3 > Flash Version: > 208 > > Rob > > From: sipx-users-boun...@list.sipfoundry.org > [mailto:sipx-users-boun...@list.sipfoundry.org] On Behalf Of Todd Hodgen > Sent: Tuesday, March 20, 2012 3:43 PM > To: 'Discussion list for users of sipXecs software' > Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated > > Might try running 5.6 or 5.8 code to see if that helps. No reason for it, > but I haven’t been running the 6.x code. Mainly because I haven’t seen > anyone state they are working with no issues on it, and I’ve seen that on the > 5.6 and 5.8 code. > > From: sipx-users-boun...@list.sipfoundry.org > [mailto:sipx-users-boun...@list.sipfoundry.org] On Behalf Of Tony Graziano > Sent: Tuesday, March 20, 2012 12:32 PM > To: Discussion list for users of sipXecs software > Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated > > Do you have an internal dns table setup on the gateway? > > I would turn up the logging level on the gateway and review that to see where > it leads you. > > On Mar 20, 2012 3:27 PM, "Jorge E. Fernandez" > <jorge.fernan...@j9consultants.com> wrote: > Im experiencing an issue with apparently random calls where they go straight > busy tone... It only happens on about 50% of calls that go out through the > gateway. When I trace the calls the gateway returns a "487 Request > Terminated" after the INVITE and when I go through the syslog from the > gateway I find this error while its handling the invite > > ( lgr_stk_ses)(10026 ) !! [ERROR] SIPStackSession::HandleStackSetupEV > failed because no remote IP > > The audiocodes is running firmware 6.0 and im running SipXecs 4.4... The > weird thing is that nothing changes from call to call its just that some go > through and some don't. Internal calling is working properly. > > Help is greatly appreciated. > > Regards, > > -- > Jorge E. Fernandez > IT Specialist > J9 IT Consultants > > jorge.fernan...@j9consultants.com > http://j9consultants.com - @jef2904 > > > > > > > > _______________________________________________ > sipx-users mailing list > sipx-users@list.sipfoundry.org > List Archive: http://list.sipfoundry.org/archive/sipx-users/ > > LAN/Telephony/Security and Control Systems Helpdesk: > Telephone: 434.984.8426 > sip: helpd...@voice.myitdepartment.net > > Helpdesk Customers: http://myhelp.myitdepartment.net > Blog: http://blog.myitdepartment.net > > > NOTICE: This electronic mail message and any content within it are intended > exclusively for the individual(s) or > entities to which it is addressed. The message, together with any attachments > and all other content, may contain > confidential and/or privileged information. Any unauthorized review, use, > print, save, copy, disclosure or distribution > is strictly prohibited. If you have received this message in error, please > immediately advise the sender by reply email > and delete all copies. > _______________________________________________ > sipx-users mailing list > sipx-users@list.sipfoundry.org > List Archive: http://list.sipfoundry.org/archive/sipx-users/ > > _______________________________________________ > sipx-users mailing list > sipx-users@list.sipfoundry.org > List Archive: http://list.sipfoundry.org/archive/sipx-users/ > > > > NOTICE: This electronic mail message and any content within it are intended > exclusively for the individual(s) or > entities to which it is addressed. The message, together with any attachments > and all other content, may contain > confidential and/or privileged information. Any unauthorized review, use, > print, save, copy, disclosure or distribution > is strictly prohibited. If you have received this message in error, please > immediately advise the sender by reply email > and delete all copies. > > > NOTICE: This electronic mail message and any content within it are intended > exclusively for the individual(s) or > entities to which it is addressed. The message, together with any attachments > and all other content, may contain > confidential and/or privileged information. Any unauthorized review, use, > print, save, copy, disclosure or distribution > is strictly prohibited. If you have received this message in error, please > immediately advise the sender by reply email > and delete all copies. > _______________________________________________ > sipx-users mailing list > sipx-users@list.sipfoundry.org > List Archive: http://list.sipfoundry.org/archive/sipx-users/
_______________________________________________ sipx-users mailing list sipx-users@list.sipfoundry.org List Archive: http://list.sipfoundry.org/archive/sipx-users/