Can anyone tell me if they know of a successful implementation of SipXecs 
utilizing both a High Availablility setup, and the ACD system?

I'm having an issue with our system whereby handset that is registered against 
the HA server (telecom-2) is unable to get an audio stream from the ACD, which 
is hosted on the primary server, (telecom-1).  Calls from handset registered 
against the primary server(telecom-1) can call the ACD without issue, and work 
properly.

We have 418 registered handsets, and a 50% ratio of sets registered on the 
primary and secondary.  All other calling features work without issue (to our 
knowledge), from handsets registered against either registrar.  In fact, it 
took awhile to narrow down the problem from "intermittent no-audio on calls to 
the ACD queue" to "calls from handsets registered on the HA server to the ACD 
Queue have no audio".

I've got packet captures of the calls from three viewpoints:

a.       The handset making the call

b.      The ACD server (telecom-1)

c.       The HA server where the handset is registered (telecom-2)

I'm not going to post packet captures publicly, but have them available if 
anyone has any ideas.

Cheers,

...Steve...

Stephen Beaudry, Manager
Server, Network and Telecom Infrastructures | Royal Roads University
T 250.391.2600 ext. 4149
2005 Sooke Road, Victoria, BC  Canada  V9B 5Y2 | 
royalroads.ca<http://royalroads.ca/>

LIFE.CHANGING