Hello, On 10/3/06, jzhang <[EMAIL PROTECTED]> wrote: > sipxtapi-dev : > > in the medialib, every 10ms, the voice data are proccessed. > Is possible for me to change the 10ms to another, such as 16ms? There are macro in mediaLib which set number of samples in one frame, but in some places of mediaLib it is assumed that media is processed in 10ms intervals. So it will not be so easy to change this interval.
Regards, Alexander Chemeris. _______________________________________________ sipxtapi-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipxtapi-dev/