Bill Moran wrote:
In response to Geoffrey <[EMAIL PROTECTED]>:
If I need to restart the postmaster on my slony replication slave,
should I shut down the slony daemons first?
If you restart the postmaster without restarting the slons, the slons
will be disconnected, sleep for a bit, then reconnect and go back to
work.
So, no, you don't have to manually restart the slons.
So I guess this makes me wonder why the slony documents warn you about
connections that are not reliable. What happens in a situation where,
say the master node goes off line temporarily? Don't the daemons keep
retrying?
--
Until later, Geoffrey
Those who would give up essential Liberty, to purchase a little
temporary Safety, deserve neither Liberty nor Safety.
- Benjamin Franklin
_______________________________________________
Slony1-general mailing list
[email protected]
http://lists.slony.info/mailman/listinfo/slony1-general