On Feb 7, 2008, at 10:01 PM, Jan Wieck wrote:

It not only can, it definitely will hurt performance. A Slony replica experiences the same updates, row per row, as the origin did. This means that the need for vacuuming is exactly the same.

Additionally, if your bloat makes your PK indexes bigger (and more sparse) then you also magnify the effect of updates that affect many rows. On the master, it would be one query but on the replica it would be expanded to individual row updates. Having to look up each PK in the index will be slowed down by the bloat.

I'd recommend taking a snapshot of your relpages numbers for each table and index from the pg_class table, running vacuum and then re- index on the big tables, then compare the relpages numbers again. Then compare performance and see how the bloat was affecting you.

_______________________________________________
Slony1-general mailing list
[email protected]
http://lists.slony.info/mailman/listinfo/slony1-general