Andrew Sullivan a écrit :
On Tue, Feb 19, 2008 at 04:30:48PM -0800, Craig James wrote:
table ..." on one of the replicated tables. Since TRUNCATE can't be handled by Slony, this lead to a duplicate-key violation in the slave database,

Ugh.  Note that you could do TRUNCATE via EXECUTE SCRIPT, I think.  Also, I
posted here an evil hack some time ago that allowed bulk loading across a
Slony node.  ISTR it had some bugs, but it might work as a starting point
for this sort of thing.

Is there any way at all to block, trap, or otherwise prevent TRUNCATE of certain tables?

No, no more than there's some way to prevent some clever person from
performing ALTER TABLE.  I regard this as one of the most severe limitations
in Slony: it will break if you do certain things, but it can't prevent you
from doing them.


Simon had provide some work (and patches) for 'trigger on truncate', check pg-hacker ML. But I am not aware of the current state of that.