On Mon, 2011-06-27 at 10:48 +0800, rodney wrote:
> Hi
> 
> I'm trying to setup slony to replicate table from one master to around
> 200 slaves. Can slony support slave number at this scale? It is observed
> in pgadmin that when I have 1 slave, the num of listener is 1. However,
> when I have 2 slaves, the num of listener increase from 1 to 4 (not 2).
> Will this be a problem if the slave go to a large number, like 100?
> 

Yes, you usually don't go over 12 or 15 nodes with Slony.


-- 
Guillaume
  http://blog.guillaume.lelarge.info
  http://www.dalibo.com

_______________________________________________
Slony1-general mailing list
[email protected]
http://lists.slony.info/mailman/listinfo/slony1-general

Reply via email to