Hi Magnus,
On 8/30/23 10:12, Hagdorn, Magnus Karl Moritz wrote:
Yes, but can you share the details of which parameters you configure
in
this plugin so that you can extract node power? This doesn't seem
obvious to me.
not much needs configuring. We have
EnergyIPMIFrequency=10
EnergyIPMICalcAdjustment=yes
EnergyIPMIPowerSensors=Node=DCMI_ENHANCED
in the acct_gather.conf.
This is a very useful example! I guess that you have also defined
EnergyIPMIUsername and EnergyIPMIPassword in acct_gather.conf? How is the
EnergyIPMIPassword protected from normal users if the
/etc/slurm/acct_gather.conf file exists?
An EnergyIPMIFrequency of 10 seconds sounds like it could put a high load
on the BMC and the server?
I have never tested IPMI DCMI_ENHANCED commands. Do you have some
FreeIMPI commands which can be used to verify the basic IPMI DCMI_ENHANCED
functionality?
Thanks,
Ole