We tried an vertical omni got crap for signal even with 500MW (2 amp might work for you) but we were in a very congested Vertical pol area so we went with two of the PAC wireless 95* Horizontal sectors and let me tell you same amps same APPO we got out to 7.25 miles and we have another remote site at 8 miles with a 500mw amp pulling backhaul from our main tower with the sectors. I can tell you this if it were nor for H pol and amps we would not have done this venture. Does not mean we will always use amps we plan on doing smaller pops with no amps to get an effective 2 to 3 mile radius if we can if not then we will use an amp if we have to. You use them in your best judgment and dont abuse it I think using them are fine o an extent but if you can avoid them I would. Sometimes you just cant..
My 2 cents Quoting Dennis Burgess <[EMAIL PROTECTED]>: > Tim, I don't doubt that sectors are the way to go, however, when cash is > tight, I need to get some clients. Right now I have none and just cash > going > out. hence, not good. > > So, a omni will hae to do for now. The reason I wanted a AMP was to get > the > maximum VBW, and max 36db power. > > Dennis > > ----- Original Message ----- > From: "Tim Foster" <[EMAIL PROTECTED]> > To: <[EMAIL PROTECTED]> > Sent: Wednesday, August 13, 2003 9:27 PM > Subject: RE: [smartBridges] Cost Effective Tower! > > > > Amps amplify signal *and* noise, so to my thinking, you'd want as little > > amping as possible. > > High gain antennas is good, but the higer the gain, the narrower the > > vertical beamwidth. > > > > Good luck and have fun figuring out what's best. ;) > > > > (I started out with a 500mw amp and a 8dB omni. Everything got *much* > better > > when I went to sectors) > > > > Tim Foster > > Aledo BroadBand > > � www.AledoBroadBand.com � > > Aledo's only high-speed ISP > > > > > -----Original Message----- > > > From: [EMAIL PROTECTED] > > > [mailto:[EMAIL PROTECTED] Behalf Of Dan @ Wyoming.com > > > Sent: Wednesday, August 13, 2003 9:06 PM > > > To: [EMAIL PROTECTED] > > > Subject: Re: [smartBridges] Cost Effective Tower! > > > > > > > > > I would at least go with a 9dbi omni. Here is the one we have been > > > using until we put up our 120 sectors. > > > > > > http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=3039990945&cate > > > gory=11175 > > > > > > Very inexpensive. > > > > > > > > > On Wed, 13 Aug 2003 20:55:25 -0500 > > > "Dennis Burgess" <[EMAIL PROTECTED]> wrote: > > > > I again, am getting ready to install my equipment on a tower. > > > > We are planing on using a 5db omni with a 1watt amp. However, we do > > > > also have to install a 19db pacwireless grid antenna on the tower > > > > also. > > > > > > > > Would this work to save cash? > > > > > > > > 19db grid backhaul connected to Airbridge Outdoor --> Ethernet > > > > running down tower into shack --> into switch -- > Into Airpoint > > > > Indoor (i do belive this has 100mw) --> Power injector for amp --> > > > > up tower to amp --> 1 foot to omni. > > > > > > > > We need to get some cash coming in first then we will upgrade to 180 > > > > sectors. > > > > > > > > Let me know > > > > > > > > Dennis > > > > > > The PART-15.ORG smartBridges Discussion List > > > To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe > > > smartBridges <yournickname> > > > To Remove: mailto:[EMAIL PROTECTED] (in the body type > > > unsubscribe smartBridges) > > > Archives: http://archives.part-15.org > > > > > > > The PART-15.ORG smartBridges Discussion List > > To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe > smartBridges <yournickname> > > To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe > smartBridges) > > Archives: http://archives.part-15.org > > > > > The PART-15.ORG smartBridges Discussion List > To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe smartBridges > <yournickname> > To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe > smartBridges) > Archives: http://archives.part-15.org > Martin Moreno Blazen Wireless 909-907-4106 www.blazenwireless.com The PART-15.ORG smartBridges Discussion List To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe smartBridges <yournickname> To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe smartBridges) Archives: http://archives.part-15.org