Title: Message
For clairification, the numbers are an OID. An MIB is the information of file that defines what each OID is. By setting 1.3.6.1.4.1.410.1.1.1.2.0 to 1 you enable the reset command. When the unit resets, this value will return to 0. Depending on your platform you may need to drop the last 0 and use 1.3.6.1.4.1.410.1.1.1.2
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Marcin
Sent: Tuesday, September 09, 2003 2:30 AM
To: [EMAIL PROTECTED]
Subject: Re: [smartBridges] SB remote reset

If I use this mib SB is suspend and need hard reset to work correctly. Why???
 
----- Original Message -----
From: Tom Haynes
Sent: Tuesday, September 09, 2003 9:00 AM
Subject: RE: [smartBridges] SB remote reset

Sorry, it is 1.3.6.1.4.1.410.1.1.1.2.0 (extra 1). sysReset requires an integer value.