Well I had have all the latest firmware on my units. I think if anything needs to be stress tested it is here in town I think at last count we had at LEAST 6 WISPS doing battle trying to get a piece of the pie and I am NOT going to let the beat me.. I may have to go to 5.7 gear pretty quick unless I can get this isolated and resolved. I spend ore and more of my day taking calls from clients trouble shooting and resting units etc. Thats all part of our commitment to them especially like today I don't have to answer my cell phone but I do I care about my clients like I would have liked my 1st WISP would have done for me but then again thats why I now have more customers then them and they are really pissed..
 
I will say it again customer service is CRUCIAL to keeping a wisp going no matter how tiring it is to you..
 
 
 
 
----- Original Message -----
Sent: Sunday, October 19, 2003 3:30 PM
Subject: RE: [smartBridges] Beta 1.0.08 locking up Ethernet anyone else??

Looks like you guys are experiencing what I had a few weeks back when I lost my whole network and had to reset my APPO every time.
 
I was not using the new firmware though.  I also was using an APPT in CB mode to feed the APPO.  I fixed it by using a separate APPO to link back to the APPT.  I upgraded the firmware to the same version an it seems to be fine now.
 
I also was doing changes when my APPO stopped associating with clients.  Good Luck!
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]On Behalf Of Blazen Wireless
Sent: Sunday, October 19, 2003 5:16 PM
To: [EMAIL PROTECTED]
Subject: Re: [smartBridges] Beta 1.0.08 locking up ethernet anyone else??

Something else too now it appears not sure due to the firmware that some of the units are losing association to the APPO or the APPO is dropping clients I have 28 on this APPO and I have to reset it for 5 of the clients to reassociate? Its seems to be a little hotter today again it was cooling off. I would say its about 100% according to local weather forecasts.. Its been showing this symptom now for the past couple of days as it has been hotter..
 
I wish this was just all a bad dream...
 
----- Original Message -----
Sent: Sunday, October 19, 2003 2:38 PM
Subject: Re: [smartBridges] Beta 1.0.08 locking up ethernet anyone else??

YES, we have seen this behavior recently........the firmware is buggy and SB does not seem to know the meaning of regression testing, so they fix one thing only to have it break something else. We have wasted numerous hours in the last few weeks on installs where signal strength is great but IP traffic won't pass. We finally get it to work thru what seems to be magic.
 
We have also seen problems on API, APPO and APPI's using the new firmware where the RSSI at the CPE is 90% but the unit won't associate. I've never seen this before.
 
It sucks to be me.
 
Bobby Bounds
Airwave Internet, LLC
 
 
 
----- Original Message -----
Sent: Sunday, October 19, 2003 11:17 AM
Subject: [smartBridges] Beta 1.0.08 locking up ethernet anyone else??

Has anyone else seen this on any of the ABO or ABI units?
I have had a few now that have NO more problems with reassociation to the tower yet about 2 -3 times a week the Ethernet TRANSMIT side shuts down as far as the statistics show when you log into the radio. It reports 1 and if you look at the receive side it is in the hundreds of thousands of bytes..
 
If you simply software reboot the radio it comes back alive and traffic starts to pass and both sides increment transmit and receive for a few days then it locks up again. It almost seems like when it auto reboots it does not bring up the Ethernet all the way. I have downgraded to 1.0.07 to confirm that it is in the firmware. This customer has about 85% rssi and 90% link quality so I don't see how it would be interference.
 
 
 
 
 
Martin & Steve
Blazen Wireless
909-326-5003
www.blazenwireless.com

Reply via email to