Hello, command : /root/smartctl-5.38 -a -d ata /dev/sdc -T permissive
Thanks for your jobs. Gerald ----- Command result follow /root/smartctl-5.38 -a -d ata /dev/sdc -T permissive smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: Hitachi HDP725050GLA360 Serial Number: GEB531RE374TRF Firmware Version: GM4OA56A User Capacity: 500,107,862,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Wed Oct 1 12:17:37 2008 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled Error SMART Status command failed Please get assistance from http://smartmontools.sourceforge.net/ Register values returned from SMART Status command are: ST =0x50 ERR=0x00 NS =0x01 SC =0x00 CL =0x00 CH =0x00 SEL=0x00 === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (7890) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 131) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 131 131 054 Pre-fail Offline - 147 3 Spin_Up_Time 0x0007 116 116 024 Pre-fail Always - 316 (Average 344) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 22 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 131 131 020 Pre-fail Offline - 29 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 319 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 22 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 34 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 34 194 Temperature_Celsius 0x0002 166 166 000 Old_age Always - 36 (Lifetime Min/Max 21/50) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 317 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. -- ASTREL "Raison & Télécom" 14 rue du perigord 69330 Meyzieu [EMAIL PROTECTED] - http://www.astrel.fr Tel: (+33/0) 4 72 45 08 16 Fax: (+33/0) 4 72 45 08 19 ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Smartmontools-database mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/smartmontools-database