yes, i know that it is an "old" drive but it works great as a firewall drive ;)
attached is the output from
smartctl -a /dev/hd?
as requested by the FAQ...
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: ST36811A
Serial Number: 3CS0B8V7
Firmware Version: 3.03
User Capacity: 6,448,619,520 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 5
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Sun Dec 14 22:39:29 2008 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 119) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: (2400) seconds.
Offline data collection
capabilities: (0x1d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0008 095 093 000 Old_age Offline
- 146126055
3 Spin_Up_Time 0x0006 099 098 000 Old_age Always
- 0
4 Start_Stop_Count 0x0013 100 100 020 Pre-fail Always
- 63
5 Reallocated_Sector_Ct 0x0013 100 100 036 Pre-fail Always
- 2
7 Seek_Error_Rate 0x0009 081 060 030 Pre-fail Offline
- 17758424543
9 Power_On_Hours 0x0012 105 001 000 Old_age Always
- 56028
10 Spin_Retry_Count 0x0013 100 100 090 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0013 100 100 000 Pre-fail Always
- 112
197 Current_Pending_Sector 0x0030 100 100 000 Old_age Offline
- 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x000a 200 188 000 Old_age Always
- 13
SMART Error Log Version: 1
ATA Error Count: 16 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 16 occurred at disk power-on lifetime: 46013 hours (1917 days + 5 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 01 ef 10 e0 Error: UNC at LBA = 0x0010ef01 = 1109761
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
20 00 01 01 ef 10 e0 00 00:01:57.320 READ SECTOR(S)
20 00 1c d5 f0 10 e0 00 00:01:57.303 READ SECTOR(S)
20 00 00 f1 ef 10 e0 00 00:01:52.242 READ SECTOR(S)
30 00 02 40 30 4b e0 00 00:01:52.242 WRITE SECTOR(S)
20 00 ef 02 ef 10 e0 00 00:01:52.210 READ SECTOR(S)
Error 15 occurred at disk power-on lifetime: 46013 hours (1917 days + 5 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 1c d5 f0 10 e0 Error: UNC at LBA = 0x0010f0d5 = 1110229
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
20 00 00 f1 ef 10 e0 00 00:01:52.242 READ SECTOR(S)
30 00 02 40 30 4b e0 00 00:01:52.242 WRITE SECTOR(S)
20 00 ef 02 ef 10 e0 00 00:01:52.210 READ SECTOR(S)
20 00 00 f1 ee 10 e0 00 00:01:47.140 READ SECTOR(S)
20 00 98 59 ee 10 e0 00 00:01:47.116 READ SECTOR(S)
Error 14 occurred at disk power-on lifetime: 46013 hours (1917 days + 5 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 ef 02 ef 10 e0 Error: UNC at LBA = 0x0010ef02 = 1109762
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
20 00 00 f1 ee 10 e0 00 00:01:47.140 READ SECTOR(S)
20 00 98 59 ee 10 e0 00 00:01:47.116 READ SECTOR(S)
20 00 b6 a3 ed 10 e0 00 00:01:47.100 READ SECTOR(S)
20 00 00 a3 ec 10 e0 00 00:01:47.078 READ SECTOR(S)
20 00 4a 59 ec 10 e0 00 00:01:47.069 READ SECTOR(S)
Error 13 occurred at disk power-on lifetime: 44474 hours (1853 days + 2 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 01 00 00 a1 Error: ICRC, ABRT at LBA = 0x01000001 = 16777217
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 01 00 00 a1 00 00:01:00.547 READ DMA
20 00 01 01 00 00 a0 00 00:00:59.990 READ SECTOR(S)
c8 00 01 01 00 00 a0 00 00:00:59.976 READ DMA
c8 00 01 01 00 00 a1 00 00:00:59.764 READ DMA
c8 00 01 01 00 00 a0 00 00:00:59.744 READ DMA
Error 12 occurred at disk power-on lifetime: 44474 hours (1853 days + 2 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 01 00 00 a1 Error: ICRC, ABRT at LBA = 0x01000001 = 16777217
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 01 00 00 a1 00 00:00:59.764 READ DMA
c8 00 01 01 00 00 a0 00 00:00:59.744 READ DMA
c8 00 01 01 00 00 a1 00 00:00:59.504 READ DMA
c8 00 01 01 00 00 a0 00 00:00:59.218 READ DMA
c8 00 01 01 00 00 a0 00 00:00:59.208 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed: read failure 70% 56028
823001
# 2 Short offline Completed without error 00% 44478 -
Device does not support Selective Self Tests/Logging
---
avast! Antivirus: Outbound message clean.
Virus Database (VPS): 081214-0, 12/14/2008
Tested on: 12/14/08 23:07:20
avast! - copyright (c) 1988-2008 ALWIL Software.
http://www.avast.com
------------------------------------------------------------------------------
SF.Net email is Sponsored by MIX09, March 18-20, 2009 in Las Vegas, Nevada.
The future of the web can't happen without you. Join us at MIX09 to help
pave the way to the Next Web now. Learn more and register at
http://ad.doubleclick.net/clk;208669438;13503038;i?http://2009.visitmix.com/
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database