yes, i know that it is an "old" drive but it works great as a firewall drive ;)

attached is the output from

smartctl -a /dev/hd?

as requested by the FAQ...
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST36811A
Serial Number:    3CS0B8V7
Firmware Version: 3.03
User Capacity:    6,448,619,520 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   5
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Sun Dec 14 22:39:29 2008 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 119) The previous self-test completed having
                                        the read element of the test failed.
Total time to complete Offline
data collection:                 (2400) seconds.
Offline data collection
capabilities:                    (0x1d) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0008   095   093   000    Old_age   Offline      
-       146126055
  3 Spin_Up_Time            0x0006   099   098   000    Old_age   Always       
-       0
  4 Start_Stop_Count        0x0013   100   100   020    Pre-fail  Always       
-       63
  5 Reallocated_Sector_Ct   0x0013   100   100   036    Pre-fail  Always       
-       2
  7 Seek_Error_Rate         0x0009   081   060   030    Pre-fail  Offline      
-       17758424543
  9 Power_On_Hours          0x0012   105   001   000    Old_age   Always       
-       56028
 10 Spin_Retry_Count        0x0013   100   100   090    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0013   100   100   000    Pre-fail  Always       
-       112
197 Current_Pending_Sector  0x0030   100   100   000    Old_age   Offline      
-       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x000a   200   188   000    Old_age   Always       
-       13

SMART Error Log Version: 1
ATA Error Count: 16 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 16 occurred at disk power-on lifetime: 46013 hours (1917 days + 5 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 01 ef 10 e0  Error: UNC at LBA = 0x0010ef01 = 1109761

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  20 00 01 01 ef 10 e0 00      00:01:57.320  READ SECTOR(S)
  20 00 1c d5 f0 10 e0 00      00:01:57.303  READ SECTOR(S)
  20 00 00 f1 ef 10 e0 00      00:01:52.242  READ SECTOR(S)
  30 00 02 40 30 4b e0 00      00:01:52.242  WRITE SECTOR(S)
  20 00 ef 02 ef 10 e0 00      00:01:52.210  READ SECTOR(S)

Error 15 occurred at disk power-on lifetime: 46013 hours (1917 days + 5 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 1c d5 f0 10 e0  Error: UNC at LBA = 0x0010f0d5 = 1110229

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  20 00 00 f1 ef 10 e0 00      00:01:52.242  READ SECTOR(S)
  30 00 02 40 30 4b e0 00      00:01:52.242  WRITE SECTOR(S)
  20 00 ef 02 ef 10 e0 00      00:01:52.210  READ SECTOR(S)
  20 00 00 f1 ee 10 e0 00      00:01:47.140  READ SECTOR(S)
  20 00 98 59 ee 10 e0 00      00:01:47.116  READ SECTOR(S)

Error 14 occurred at disk power-on lifetime: 46013 hours (1917 days + 5 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 ef 02 ef 10 e0  Error: UNC at LBA = 0x0010ef02 = 1109762

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  20 00 00 f1 ee 10 e0 00      00:01:47.140  READ SECTOR(S)
  20 00 98 59 ee 10 e0 00      00:01:47.116  READ SECTOR(S)
  20 00 b6 a3 ed 10 e0 00      00:01:47.100  READ SECTOR(S)
  20 00 00 a3 ec 10 e0 00      00:01:47.078  READ SECTOR(S)
  20 00 4a 59 ec 10 e0 00      00:01:47.069  READ SECTOR(S)

Error 13 occurred at disk power-on lifetime: 44474 hours (1853 days + 2 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 01 00 00 a1  Error: ICRC, ABRT at LBA = 0x01000001 = 16777217

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 01 01 00 00 a1 00      00:01:00.547  READ DMA
  20 00 01 01 00 00 a0 00      00:00:59.990  READ SECTOR(S)
  c8 00 01 01 00 00 a0 00      00:00:59.976  READ DMA
  c8 00 01 01 00 00 a1 00      00:00:59.764  READ DMA
  c8 00 01 01 00 00 a0 00      00:00:59.744  READ DMA

Error 12 occurred at disk power-on lifetime: 44474 hours (1853 days + 2 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 01 00 00 a1  Error: ICRC, ABRT at LBA = 0x01000001 = 16777217

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 01 01 00 00 a1 00      00:00:59.764  READ DMA
  c8 00 01 01 00 00 a0 00      00:00:59.744  READ DMA
  c8 00 01 01 00 00 a1 00      00:00:59.504  READ DMA
  c8 00 01 01 00 00 a0 00      00:00:59.218  READ DMA
  c8 00 01 01 00 00 a0 00      00:00:59.208  READ DMA

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed: read failure       70%     56028         
823001
# 2  Short offline       Completed without error       00%     44478         -

Device does not support Selective Self Tests/Logging

---
avast! Antivirus: Outbound message clean.
Virus Database (VPS): 081214-0, 12/14/2008
Tested on: 12/14/08 23:07:20
avast! - copyright (c) 1988-2008 ALWIL Software.
http://www.avast.com



------------------------------------------------------------------------------
SF.Net email is Sponsored by MIX09, March 18-20, 2009 in Las Vegas, Nevada.
The future of the web can't happen without you.  Join us at MIX09 to help
pave the way to the Next Web now. Learn more and register at
http://ad.doubleclick.net/clk;208669438;13503038;i?http://2009.visitmix.com/
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to