smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     FUJITSU MHZ2250BJ FFS G2
Serial Number:    K83ET9226FN9
Firmware Version: 0085001C
User Capacity:    250,059,350,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 3f
Local Time is:    Sat May  2 00:38:40 2009 BRT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 ( 812) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 111) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   046    Pre-fail  Always       
-       109636
  3 Spin_Up_Time            0x0003   100   100   025    Pre-fail  Always       
-       2
  5 Reallocated_Sector_Ct   0x0033   100   100   024    Pre-fail  Always       
-       8589934592000
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       5957
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       42
191 G-Sense_Error_Rate      0x0012   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       8
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       2104
194 Temperature_Celsius     0x0022   100   095   000    Old_age   Always       
-       47 (Lifetime Min/Max 24/61)
199 UDMA_CRC_Error_Count    0x0032   100   100   000    Old_age   Always       
-       853632
200 Multi_Zone_Error_Rate   0x0032   100   100   000    Old_age   Always       
-       918286
240 Head_Flying_Hours       0x0032   100   100   000    Old_age   Always       
-       4628
241 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       51165064069122
242 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       96462155808770
254 Unknown_Attribute       0x0032   253   253   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%        97         -
# 2  Conveyance offline  Completed without error       00%        22         -
# 3  Short offline       Completed without error       00%         4         -
# 4  Short offline       Completed without error       00%         2         -
# 5  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Register Now & Save for Velocity, the Web Performance & Operations 
Conference from O'Reilly Media. Velocity features a full day of 
expert-led, hands-on workshops and two days of sessions from industry 
leaders in dedicated Performance & Operations tracks. Use code vel09scf 
and Save an extra 15% before 5/3. http://p.sf.net/sfu/velocityconf
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to