Please find smartctl -a output enclosed, according to FAQ:
Thanks, Audris
*>If your drive is not in the database of the current release,* to have
it added to the database, first use the command:
> smartctl -t short /dev/hd?
>to run a short self-test on the drive, and wait a few minutes for the
test to complete. Then email the entire output from:
> smartctl -a /dev/hd?
> to smartmontools-database
<https://lists.sourceforge.net/lists/listinfo/smartmontools-database> as
a plain-text ASCII email attachment (file type: ".txt"). The timestamp
in the self-test log will help us to determine whether > Attribute 9 is
being used to store the lifetime in hours, minutes, or seconds.
smartctl 5.39 2009-08-08 r2872~ [x86_64-unknown-linux-gnu] (openSUSE RPM)
Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: Hitachi HDS722020ALA330
Serial Number: JK1100YAG5ZUZT
Firmware Version: JKAOA20N
User Capacity: 2,000,398,934,016 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Mon Apr 12 09:55:05 2010 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command
from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (22918) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 093 093 016 Pre-fail Always
- 32
2 Throughput_Performance 0x0005 132 132 054 Pre-fail Offline
- 105
3 Spin_Up_Time 0x0007 136 136 024 Pre-fail Always
- 573 (Average 490)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always
- 10
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always
- 1
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always
- 0
8 Seek_Time_Performance 0x0005 112 112 020 Pre-fail Offline
- 39
9 Power_On_Hours 0x0012 100 100 000 Old_age Always
- 3445
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 10
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 72
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always
- 72
194 Temperature_Celsius 0x0002 130 130 000 Old_age Always
- 46 (Lifetime Min/Max 22/54)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 1
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always
- 0
SMART Error Log Version: 0
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 3445 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Download Intel® Parallel Studio Eval
Try the new software tools for yourself. Speed compiling, find bugs