I have a Vertex 4 behind an IBM M5110e (roughly an LSI 9270-8i PCI 3.0).
The OCZ forum guy is telling me that the info is wrong.
I followed your web site instructions and have attached vertex4.txt. I
tried the test first but nothing was returned.
Thanks!!
--
personal Signature
------------------------------------------------------------------------
Andrew McIntyre
[email protected] <mailto:[email protected]>
http://www.mindspring.com/~amcintyr/resume.htm
<http://www.mindspring.com/%7Eamcintyr/resume.htm>
------------------------------------------------------------------------
andrew@sherlock:/var/log$ sudo smartctl -a -d sat+megaraid,3 /dev/sda
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.2.0-29-generic] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: OCZ-VERTEX4
Serial Number: OCZ-216S1Y30VGHMGJK9
LU WWN Device Id: 5 e83a97 aa40c6250
Firmware Version: 1.5
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ACS-2 (revision not indicated)
Local Time is: Tue Sep 4 19:27:41 2012 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x1d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging NOT supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 0) minutes.
Extended self-test routine
recommended polling time: ( 0) minutes.
SMART Attributes Data Structure revision number: 18
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0000 006 000 000 Old_age Offline
- 6
3 Spin_Up_Time 0x0000 100 100 000 Old_age Offline
- 0
4 Start_Stop_Count 0x0000 100 100 000 Old_age Offline
- 0
5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline
- 0
9 Power_On_Hours 0x0000 100 100 000 Old_age Offline
- 238
12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline
- 6
232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline
- 1606465066
233 Media_Wearout_Indicator 0x0000 100 000 000 Old_age Offline
- 100
SMART Error Log not supported
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and
threat landscape has changed and how IT managers can respond. Discussions
will include endpoint security, mobile security and the latest in malware
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database