Please add the ST6000NM0024-1HT17Z device to your database.
And thanks for the great tool and keep up the good work.
--
http://www.linum.com mailto:[email protected]
Linum Software GmbH, Langer Wall 5, 37574 Einbeck, Germany
Tel: +49-5561-926730 Fax: +49-5561-926750
Handelsregister Amtsgericht Göttingen HRB 131128 / Geschäftsführer
Claas-Jörg Hilbrecht
smartctl 6.4 2014-09-29 r3990 [x86_64-linux-3.2.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST6000NM0024-1HT17Z
Firmware Version: SN02
User Capacity: 6.001.175.126.016 bytes [6,00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Dec 9 22:43:23 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 89) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 636) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x50bd) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 076 063 044 - 45546059
3 Spin_Up_Time PO---- 099 099 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 1
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
7 Seek_Error_Rate POSR-- 063 060 030 - 2604196
9 Power_On_Hours -O--CK 100 100 000 - 7
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 1
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 057 054 045 - 43 (Min/Max 18/46)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
193 Load_Cycle_Count -O--CK 100 100 000 - 4
194 Temperature_Celsius -O---K 043 046 000 - 43 (0 18 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 069 042 000 - 45546059
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL,SL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x15 GPL - 1 Reserved for Serial ATA
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x24 GPL R/O 512 Current Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 8160 Device vendor specific log
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 8982 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc1 GPL,SL VS 10 Device vendor specific log
0xc3 GPL,SL VS 8 Device vendor specific log
0xc7 GPL,SL VS 1 Device vendor specific log
0xd1 GPL,SL VS 8 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 6 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 18/45 Celsius
Lifetime Min/Max Temperature: 18/45 Celsius
Under/Over Temperature Limit Count: 0/8
SCT Temperature History Version: 2
Temperature Sampling Period: 3 minutes
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 128 (9)
Index Estimated Time Temperature Celsius
10 2014-12-04 17:17 ? -
... ..(116 skipped). .. -
127 2014-12-09 12:20 ? -
0 2014-12-09 13:19 30 ***********
1 2014-12-09 14:18 ? -
2 2014-12-09 15:17 18 -
3 2014-12-09 16:16 41 **********************
4 2014-12-09 17:15 45 **************************
5 2014-12-09 18:14 45 **************************
6 2014-12-09 19:13 44 *************************
... ..( 2 skipped). .. *************************
9 2014-12-09 22:10 44 *************************
SCT Error Recovery Control:
Read: 100 (10,0 seconds)
Write: 100 (10,0 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 2) ==
1 0x008 4 1 Lifetime Power-On Resets
1 0x010 4 7 Power-on Hours
1 0x018 6 3139271 Logical Sectors Written
1 0x020 6 13862 Number of Write Commands
1 0x028 6 8751264111 Logical Sectors Read
1 0x030 6 15712508 Number of Read Commands
1 0x038 6 - Date and Time TimeStamp
3 ===== = = == Rotating Media Statistics (rev 1) ==
3 0x008 4 7 Spindle Motor Power-on Hours
3 0x010 4 7 Head Flying Hours
3 0x018 4 4 Head Load Events
3 0x020 4 0 Number of Reallocated Logical Sectors
3 0x028 4 0 Read Recovery Attempts
3 0x030 4 0 Number of Mechanical Start Failures
4 ===== = = == General Errors Statistics (rev 1) ==
4 0x008 4 0 Number of Reported Uncorrectable Errors
4 0x010 4 0 Resets Between Cmd Acceptance and Completion
5 ===== = = == Temperature Statistics (rev 1) ==
5 0x008 1 43~ Current Temperature
5 0x010 1 1~ Average Short Term Temperature
5 0x018 1 0~ Average Long Term Temperature
5 0x020 1 42~ Highest Temperature
5 0x028 1 18~ Lowest Temperature
5 0x038 1 1~ Lowest Average Short Term Temperature
5 0x048 1 0~ Lowest Average Long Term Temperature
5 0x050 4 0 Time in Over-Temperature
5 0x058 1 55 Specified Maximum Operating Temperature
5 0x060 4 0 Time in Under-Temperature
5 0x068 1 13 Specified Minimum Operating Temperature
6 ===== = = == Transport Statistics (rev 1) ==
|_ ~ normalized value
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
------------------------------------------------------------------------------
Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server
from Actuate! Instantly Supercharge Your Business Reports and Dashboards
with Interactivity, Sharing, Native Excel Exports, App Integration & more
Get technology previously reserved for billion-dollar corporations, FREE
http://pubads.g.doubleclick.net/gampad/clk?id=164703151&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database