Hello,
Someone gave me a laptop on which he had installed this Kingston SSD
via an "HDD caddy", to reinstall his OS (linux). The drive is
unpartitioned and apparently it hasn't seen any use, apart from
powering on and off with the rest of the system. What I found odd were
the reported values for the
Runtime_Bad_Block attribute, which seems to indicate that the drive is
failing and the second temperature reading - it certainly doesn't feel
to the touch like it has reached 100°C, 31°C seems to be more
accurate.
If you have any questions or you'd like me to run any tests, I'll have
it available for the weekend.
Best Regards
Alex
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-65-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: KINGSTON SHSS37A240G
Serial Number: 50026B7258082502
Firmware Version: SAFM00.r
User Capacity: 240.057.409.536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Oct 9 23:50:59 2015 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 30) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Spin_Up_Time POS--- 100 100 050 - 0
5 Reallocated_Sector_Ct PO--C- 100 100 050 - 0
7 Unknown_SSD_Attribute PO-R-- 100 100 050 - 0
8 Unknown_SSD_Attribute P-S--- 100 100 050 - 0
9 Power_On_Hours -O--C- 100 100 000 - 209
12 Power_Cycle_Count -O--C- 100 100 000 - 65
168 Unknown_Attribute -O--C- 100 100 000 - 0
170 Unknown_Attribute PO---- 100 100 010 - 598
173 Unknown_Attribute -O--C- 100 100 000 - 1
175 Program_Fail_Count_Chip PO--C- 100 100 050 - 0
183 Runtime_Bad_Block -O--C- 100 100 100 NOW 65536
187 Reported_Uncorrect -O--C- 100 100 000 - 0
192 Power-Off_Retract_Count -O--C- 100 100 000 - 4
194 Temperature_Celsius PO---K 069 055 030 - 31 (Min/Max 24/45)
196 Reallocated_Event_Count -O---- 100 100 010 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
199 UDMA_CRC_Error_Count PO-R-- 100 100 050 - 0
218 Unknown_Attribute PO-R-- 100 100 050 - 0
231 Temperature_Celsius PO--C- 100 100 000 - 100
233 Media_Wearout_Indicator PO-R-- 100 100 000 - 4
240 Unknown_SSD_Attribute PO--C- 100 100 000 - 0
241 Total_LBAs_Written -O--C- 100 100 000 - 4
242 Total_LBAs_Read -O--C- 100 100 000 - 4
244 Unknown_Attribute -O---- 100 100 000 - 0
245 Unknown_Attribute -O---- 100 100 000 - 1
246 Unknown_Attribute -O--C- 100 100 000 - 2112
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 6 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x30 GPL,SL R/O 8 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 209 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 2) ==
1 0x008 4 65 Lifetime Power-On Resets
1 0x018 6 8721630 Logical Sectors Written
1 0x020 6 11791 Number of Write Commands
1 0x028 6 8398236 Logical Sectors Read
1 0x030 6 16200 Number of Read Commands
4 ===== = = == General Errors Statistics (rev 1) ==
4 0x008 4 11 Number of Reported Uncorrectable Errors
4 0x010 4 0 Resets Between Cmd Acceptance and Completion
5 ===== = = == Temperature Statistics (rev 1) ==
5 0x008 1 32 Current Temperature
5 0x010 1 32 Average Short Term Temperature
5 0x018 1 32 Average Long Term Temperature
5 0x020 1 50 Highest Temperature
5 0x028 1 5 Lowest Temperature
5 0x030 1 50 Highest Average Short Term Temperature
5 0x038 1 16 Lowest Average Short Term Temperature
5 0x040 1 50 Highest Average Long Term Temperature
5 0x048 1 16 Lowest Average Long Term Temperature
5 0x050 4 0 Time in Over-Temperature
5 0x058 1 50 Specified Maximum Operating Temperature
5 0x060 4 0 Time in Under-Temperature
5 0x068 1 5 Specified Minimum Operating Temperature
6 ===== = = == Transport Statistics (rev 1) ==
6 0x008 4 176 Number of Hardware Resets
6 0x018 4 0 Number of Interface CRC Errors
7 ===== = = == Solid State Device Statistics (rev 1) ==
7 0x008 1 5 Percentage Used Endurance Indicator
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 4 148 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 210 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database