Hi,
I have a Plextor PX256-M3P, which is making some trouble. That's why I issued
multiple selftest commands. When inspecting the selftest logs, I wondered about
the LifeTime, which is completely different from SMART attribute 9. The
attached log shows the situation. I would be glad if you could correct the
display of the selftest logs for this drive type.
smartctl 6.4 2015-06-04 r4109 [x86_64-w64-mingw32-win7-sp1] (sf-6.4-1)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Plextor M3/M5/M6 Series SSDs
Device Model: PLEXTOR PX-256M3P
Add. Product Id: VRPR
Firmware Version: 1.06
User Capacity: 256.060.514.304 bytes [256 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a
SATA Version is: SATA 3.0, 6.0 Gb/s
Local Time is: Tue Dec 22 16:19:45 2015 MZ
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x05) Offline data collection activity
was aborted by an interrupting command
from host.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 10) seconds.
Offline data collection
capabilities: (0x15) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO---- 100 100 070 - 0
5 Reallocated_Sector_Ct PO---- 100 100 000 - 0
9 Power_On_Hours -O---- 100 100 000 - 1422
12 Power_Cycle_Count -O---- 100 100 000 - 2240
177 Wear_Leveling_Count PO---- 100 100 000 - 28378
178 Used_Rsvd_Blk_Cnt_Chip PO---- 100 100 000 - 21
181 Program_Fail_Cnt_Total PO---- 100 100 000 - 0
182 Erase_Fail_Count_Total PO---- 100 100 000 - 0
187 Reported_Uncorrect -O---- 100 100 000 - 49
192 Power-Off_Retract_Count PO---- 100 100 000 - 94
196 Reallocated_Event_Count PO---- 100 100 000 - 49
198 Offline_Uncorrectable PO---- 100 100 000 - 0
199 UDMA_CRC_Error_Count PO---- 100 100 000 - 28
232 Available_Reservd_Space PO---- 098 098 010 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 0
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x10 GPL,SL R/O 1 SATA NCQ Queued Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 1 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
Warning: ATA error count 0 inconsistent with error log pointer 1
ATA Error Count: 0
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 0 occurred at disk power-on lifetime: 768 hours (32 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 53 00 00 01 01 30
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
53 00 00 00 01 01 30 00 40d+19:08:49.015 [RESERVED]
53 00 00 00 01 01 30 08 08:02:56.631 [RESERVED]
53 00 00 00 01 03 30 08 43d+09:22:11.063 [RESERVED]
53 00 00 00 01 02 30 08 42d+23:58:34.487 [RESERVED]
53 00 00 00 01 01 30 00 42d+14:30:35.767 [RESERVED]
Error -3 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 00 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
00 03 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand]
[OBS-ACS-2]
Error -4 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 01 00 00 00 00 01 Error:
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
00 40 00 00 00 00 00 a5 00:00:00.000 NOP [Reserved subcommand]
[OBS-ACS-2]
01 d6 00 00 00 00 01 22 7d+08:56:05.680 [RESERVED]
03 d4 00 00 00 00 01 1e 7d+08:56:05.680 CFA REQUEST EXTENDED ERROR
02 00 00 00 00 00 01 00 7d+08:56:05.680 [RESERVED]
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Extended offline Completed without error 00% 35333 -
# 2 Extended offline Completed without error 00% 35077 -
# 3 Extended offline Completed: read failure 90% 34821
286295552
# 4 Extended offline Completed: read failure 90% 32773
284218368
# 5 Extended offline Completed: read failure 90% 32517
338552320
# 6 Extended offline Completed: read failure 90% 32261
283265536
# 7 Extended offline Completed without error 00% 31493 -
# 8 Extended offline Completed without error 00% 31493 -
# 9 Extended offline Completed: read failure 90% 31237
302961152
#10 Extended offline Completed: read failure 90% 31237
264429568
#11 Short offline Completed without error 00% 7424 -
#12 Offline Completed: read failure 100% 30981
340627200
#13 Offline Completed: read failure 100% 28677
340627200
#14 Offline Completed: read failure 100% 28677
254952704
#15 Offline Completed: read failure 100% 28677
254952704
#16 Extended offline Completed without error 00% 56066 -
#17 Extended offline Completed without error 00% 48386 -
#18 Extended offline Completed without error 00% 47106 -
#19 Extended offline Completed without error 00% 45570 -
10 of 10 failed self-tests are outdated by newer successful extended offline
self-test # 1
Selective Self-tests/Logging not supported
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: ? Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 0 minutes
Temperature Logging Interval: 0 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (0)
Index Estimated Time Temperature Celsius
1 2015-12-22 14:12 ? -
... ..(126 skipped). .. -
0 2015-12-22 16:19 ? -
SCT Error Recovery Control:
Read: 2 (0,2 seconds)
Write: 2 (0,2 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database