Hi,
my SSD seems missing from the database.
i have followed
https://www.smartmontools.org/wiki/FAQ#MyATAdriveisnotinthesmartctlsmartddatabase
(and first updated the database)
Thanks,
Daniele
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.14.56-gentoo-Dom0-314-r4] (local
build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: Corsair Neutron GTX SSD
Serial Number: 14087914000097140111
Firmware Version: M311
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 6.0 Gb/s
Local Time is: Tue Dec 29 15:50:29 2015 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: ATA return descriptor not supported by controller
firmware
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4) seconds.
Offline data collection
capabilities: (0x19) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -OSR-- 166 166 006 - 0
5 Reallocated_Sector_Ct -O--CK 253 253 036 - 0
9 Power_On_Hours -O--CK 083 083 000 - 15598
12 Power_Cycle_Count -O--CK 100 100 000 - 43
171 Unknown_Attribute -O--CK 253 253 000 - 0
172 Unknown_Attribute -O--CK 253 253 000 - 0
181 Program_Fail_Cnt_Total -O--CK 253 253 000 - 0
182 Erase_Fail_Count_Total -O--CK 253 253 000 - 0
194 Temperature_Celsius -O---- 027 000 000 - 27 (Min/Max 18/40)
201 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
204 Soft_ECC_Correction -OSR-- 100 100 000 - 0
231 Temperature_Celsius PO--CK 098 098 010 - 3
234 Unknown_Attribute -O--CK 100 100 000 - 20751
241 Total_LBAs_Written -O--CK 100 100 000 - 13855
242 Total_LBAs_Read -O--CK 100 100 000 - 13391
250 Read_Error_Retry_Rate -O--CK 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 4 Comprehensive SMART error log
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x04 SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 36302 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 36302 occurred at disk power-on lifetime: 15598 hours (649 days + 22
hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 ff 00 4f c2 e0 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b0 d5 81 04 4f c2 00 00 4d+19:53:16.080 SMART READ LOG
b0 d5 01 04 4f c2 00 00 4d+19:53:16.080 SMART READ LOG
b0 d5 01 06 4f c2 00 00 4d+19:53:16.080 SMART READ LOG
b0 d5 01 01 4f c2 00 00 4d+19:53:16.070 SMART READ LOG
b0 d5 01 00 4f c2 00 00 4d+19:53:16.070 SMART READ LOG
Error 36301 occurred at disk power-on lifetime: 15528 hours (647 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 00 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
e0 00 00 00 00 00 00 00 1d+21:21:04.350 STANDBY IMMEDIATE
ea 00 00 00 00 00 00 00 1d+21:21:04.350 FLUSH CACHE EXT
ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT
ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT
61 08 00 00 08 00 40 40 1d+21:21:02.090 WRITE FPDMA QUEUED
Error 36300 occurred at disk power-on lifetime: 15528 hours (647 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 00 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
e0 00 00 00 00 00 00 00 1d+21:21:04.350 STANDBY IMMEDIATE
ea 00 00 00 00 00 00 00 1d+21:21:04.350 FLUSH CACHE EXT
ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT
ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT
61 08 00 00 08 00 40 40 1d+21:21:02.090 WRITE FPDMA QUEUED
Error 36299 occurred at disk power-on lifetime: 15482 hours (645 days + 2 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 00 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
Error 36298 occurred at disk power-on lifetime: 15482 hours (645 days + 2 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 00 00 00 00 00 00 at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
61 00 18 00 61 d9 40 40 04:58:19.000 WRITE FPDMA QUEUED
61 08 10 f8 60 d9 40 40 04:58:19.000 WRITE FPDMA QUEUED
61 08 00 00 60 d9 40 40 04:58:19.000 WRITE FPDMA QUEUED
61 00 08 00 5f d9 40 40 04:58:19.000 WRITE FPDMA QUEUED
61 00 10 00 5e d9 40 40 04:58:19.000 WRITE FPDMA QUEUED
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 15598 -
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (SMART Log 0x04)
Page Offset Size Value Flags Description
ATA_SMART_READ_LOG failed: megasas_cmd result: 4.18 = 0/45
Read Device Statistics pages 0x00-0x80 failed
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database