Hi,
This is an older model SSD (but brand-new and unused) that I had lying
around, and finally decided to use it. It doesn't support logging the
tests, so even though I did run a short test as per the wiki
instructions, it's not reflected in the smartctl dump.
It appears to have similar attributes to the older OCZ VERTEX2; at least
2 of them match expectations for me if I manually change the drivedb.h
file to use the same definitions:
9 Power_On_Hours_and_Msec 0x0032 047 047 000 Old_age
Always - 13h+03m+14.020s
241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always
- 220
The drive has been up for about that long (approx 13 hours, since late
last night) and has been written over once (minus a few GB at the end)
with a dd copy, so the 220GB written makes sense.
Thanks,
-Ion
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.9.9-100.fc24.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: OCZ-VERTEX3 LT
Serial Number: OCZ-26R419XC5Y57LM6K
LU WWN Device Id: 5 e83a97 ef01b0605
Firmware Version: 2.22
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Feb 15 10:02:01 2017 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 050 - 3573118
5 Reallocated_Sector_Ct PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 047 047 000 - 13 (123 40 0)
12 Power_Cycle_Count -O--CK 100 100 000 - 5
171 Unknown_Attribute -O--CK 000 000 000 - 0
172 Unknown_Attribute -O--CK 000 000 000 - 0
174 Unknown_Attribute ----CK 000 000 000 - 5
177 Wear_Leveling_Count ------ 000 000 000 - 0
181 Program_Fail_Cnt_Total -O--CK 000 000 000 - 0
182 Erase_Fail_Count_Total -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 030 030 000 - 30 (Min/Max 30/30)
195 Hardware_ECC_Recovered --SRC- 120 120 000 - 3573118
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unknown_SSD_Attribute --SRC- 120 120 000 - 3573118
204 Soft_ECC_Correction --SRC- 120 120 000 - 3573118
230 Unknown_SSD_Attribute PO--C- 100 100 000 - 100
231 Temperature_Celsius PO--C- 100 100 010 - 0
233 Media_Wearout_Indicator ------ 000 000 000 - 171
234 Unknown_Attribute -O--CK 000 000 000 - 220
241 Total_LBAs_Written -O--CK 000 000 000 - 220
242 Total_LBAs_Read -O--CK 000 000 000 - 4
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xb7 GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 30/30 Celsius
Lifetime Min/Max Temperature: 30/30 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 0 minutes
Temperature Logging Interval: 0 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 478 (1)
Index Estimated Time Temperature Celsius
2 2017-02-15 02:05 ? -
... ..(476 skipped). .. -
1 2017-02-15 10:02 ? -
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
------------------------------------------------------------------------------