Hi Kevin, Today Kevin Neal wrote:
> Hello everyone, > Over the holiday I added a lot of new targets to my configuration, > I'm now running into this error: > > "FPing: WARNING: smokeping took 78 seconds to complete 1 round of > polling. It should complete polling in 60 seconds. You may have > unresponsive devices in your setup." > > I don't have any unresponsive devices but do have a lot of devices and > firing off a round every 60 seconds. I also see where smokeping is > doing this: > > "Not entering multiprocess mode for just a single probe." > > I am curious if I can force multiprocess mode, or if it would make any > difference since it is a single probe defined. If there are any other > optimizations that I could do I'd be interested in that as well. Here > is my FPing probe configuration: > > + FPing" > > binary = /usr/sbin/fping > blazemode = true > you can create two instances of the FPing probe and asigned half the targets to one and the other half to the second probe ... cheers tobi > > > -Kevin > > _______________________________________________ > smokeping-users mailing list > [email protected] > https://lists.oetiker.ch/cgi-bin/listinfo/smokeping-users > > -- Tobi Oetiker, OETIKER+PARTNER AG, Aarweg 15 CH-4600 Olten, Switzerland http://it.oetiker.ch [email protected] ++41 62 775 9902 / sb: -9900 _______________________________________________ smokeping-users mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/smokeping-users