"If there is too small a charge current there will not be a "end of charge curve" and the computer won't know when to stop..."
That explains what I have observed. Regis --- In [EMAIL PROTECTED], George Joy <[EMAIL PROTECTED]> wrote: > Tom and all, > You are correct, and you should NOT start the charge over to fill a > larger NiMH cell. You can do this with any large NiCd cell. > Our charge circuit uses the "end of charge" voltage curve to > determine when the pack will reach peak. A NiCd cell will develop and "end > of charge" curve at almost any charge current, but a NiMH cell needs a > minimum amount of current, depending on size, to develop that voltage > curve. If there is too small a charge current there will not be a "end of > charge curve" and the computer won't know when to stop, so there goes the > pack,poof :-). > We warrantee the charger will SAFELY charge NiMH cells up to 1200 mAh > for the Pro Series and up to 3000 mAh for the upgraded version. > Also you are correct about the switch, it will not change the charge > current. > Smooth Landings > George > > At 05:45 PM 7/28/2003 -0700, Tom Watson wrote: > >Hold on there...the Pro series won't handle NiMH RX packs above 1200 MAh > >(check the manual on this - I'm pretty sure about the size), unless the > >charge cycle is started over once complete. Setting the selector switch > >doesn't alter the charge current. Following is a direct quote from George > >Joy from a while back: > > > >"There is a misconception about the switch on the Pro Series charger, it > >does not change the charge current, it only sets the "Maintenance Mode" > >charge profile, and an emergency shutdown mode. You cannot "slow" charge a > >pack by putting the switch in the lowest position. If you try this with a > >pack above 500 mAh it will never get it full, the emergency shutdown mode > >will terminate the charge before it is full." > > > >The Pro series must be modified to handle big packs and the Sirius guys can > >provide this service. > > > >Tom > > > > > >----- Original Message ----- > >From: "Andrew E. Mileski" <[EMAIL PROTECTED]> > >To: <[EMAIL PROTECTED]> > >Sent: Monday, July 28, 2003 5:00 PM > >Subject: Re: [RCSE] Charger Question > > > > > > > Pat McCleave wrote: > > > > > > > I just received a new 2000ma Nimh Battery with my new NYX F3F and I was > > > > wondering if I will be able to charge it with my Sirius Pro Charger. > > > > > > Set it to 200 mA and it will charge overnight. Most Ni-MH can handle > > > a C rate (2000 mA) for a 1 hour charge, and if in a real hurray some > > > can deal with 2C or more (check the cell specs). > > > > > > >RCSE-List facilities provided by Model Airplane News. Send "subscribe" > >and "unsubscribe" requests to [EMAIL PROTECTED] Please note > >that subscribe and unsubscribe messages must be sent in text only format > >with MIME turned off. > > > > RCSE-List facilities provided by Model Airplane News. Send "subscribe" and "unsubscribe" requests to [EMAIL PROTECTED] Please note that subscribe and unsubscribe messages must be sent in text only format with MIME turned off. RCSE-List facilities provided by Model Airplane News. Send "subscribe" and "unsubscribe" requests to [EMAIL PROTECTED] Please note that subscribe and unsubscribe messages must be sent in text only format with MIME turned off.