On Fri, Feb 05, 2010 at 09:09:35PM +0100, Wolfgang Grandegger wrote:
> 
> OK, the preliminary patch for SVN below implements this solution and shows
> what we are speaking about. As a nice side effect, it also allows to check
> if the device supports bus-error reporting. Marc, could you please check
> the at91_can modifications?
With regard to the bus error interrupts, the patch looks good.
When I get some time, I can make the softing driver act appropriate.

Thanks,
Kurt
> 
> Wolfgang.
> 
> 
> [PATCH/RFC] make bus-error generation configurable via netlink interface
> 
> By default, bus-error generation is *disabled* and it can be enabled
> with: "ip link set can0 up type can bitrate 500000 bus-error 1".
> 
> Signed-off-by: Wolfgang Grandegger <[email protected]>
_______________________________________________
Socketcan-users mailing list
[email protected]
https://lists.berlios.de/mailman/listinfo/socketcan-users

Reply via email to