On Wed, 2 Apr 2008, [UTF-8] Lars Noodén wrote:
> Michael Greenish wrote: > > > Any one seen this before with their Soerkis box? Any suggestions? > > Not that specifically. I have seen with a 4801 that some subnets I have > to work with will not let me use a normal cross-over Ethernet cable with > the Soekris unit. But those particular wall plugs do work with a > straight-through (usually they're orange) cable as well as with a > cross-over if I connect first to a hub and then to the 4801. That was my first thought also on reading the original post. The 4501 appears to be MDI only and likely the Linux box is as well while the router is either auto MDI or MDI-X. That would be consistent with the described symptoms, in that both work with the router and not with each other. Try an Ethernet crossover cable between the 4501 and Linux box or a hub and straight cables. -Jed _______________________________________________ Soekris-tech mailing list [email protected] http://lists.soekris.com/mailman/listinfo/soekris-tech
