Hi Guys, I am facing a strange problem right now with my SUN FIRE v480 servers. There are about 9 servers distributed into two racks, some of them having D240 or Storedge 3310 attached with SCSI. Now the fact is in all servers having external SCSI storage (D240 or 3310) I am getting the following error in /var/adm/messages again and again:
Aug 5 08:07:26 air01a scsi: [ID 107833 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0/[EMAIL PROTECTED],0 (ssd0): Aug 5 08:07:26 air01a SCSI transport failed: reason 'reset': retrying command Aug 5 08:07:27 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:07:27 air01a FCP: WWN 0x500000e010772c71 reset successfully Aug 5 08:07:28 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:07:28 air01a FCP: WWN 0x500000e010772c71 reset successfully Aug 5 08:07:29 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:07:29 air01a FCP: WWN 0x500000e010772c71 reset successfully Aug 5 08:07:30 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:07:30 air01a FCP: WWN 0x500000e010772c71 reset successfully Aug 5 08:12:23 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:12:23 air01a FCP: WWN 0x500000e010717e91 reset successfully Aug 5 08:12:24 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:12:24 air01a FCP: WWN 0x500000e010717e91 reset successfully Aug 5 08:12:25 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:12:25 air01a FCP: WWN 0x500000e010717e91 reset successfully Aug 5 08:12:26 air01a scsi: [ID 243001 kern.warning] WARNING: /[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0): Aug 5 08:12:26 air01a FCP: WWN 0x500000e010717e91 reset successfully Here it should be noted that all these errors are only showing for the servers having external SCSI storage but the read/write operation is ok on the disks except one 3310 on which oracle database was installed. I have checked sunsolve and found that it may happen for wrong maxcontig value, but for my case I checked and confirmed that the value is 128 which is okay for SCSI. So, can anyone help me out by telling some more factors which can cause this error log to be generated? Thanks in advance. -- Best Regards, Mahfuz _______________________________________________ Solaris-Users mailing list [EMAIL PROTECTED] http://www.filibeto.org/mailman/listinfo/solaris-users