Hi Guys, I am facing a strange problem right now with my SUN FIRE v480
servers. There are about 9 servers distributed into two racks, some of
them having D240 or Storedge 3310 attached with SCSI. Now the fact is
in all servers having external SCSI storage (D240 or 3310) I am
getting the following error in /var/adm/messages again and again:

Aug  5 08:07:26 air01a scsi: [ID 107833 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0/[EMAIL 
PROTECTED],0 (ssd0):
Aug  5 08:07:26 air01a  SCSI transport failed: reason 'reset': retrying command
Aug  5 08:07:27 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:07:27 air01a  FCP: WWN 0x500000e010772c71 reset successfully
Aug  5 08:07:28 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:07:28 air01a  FCP: WWN 0x500000e010772c71 reset successfully
Aug  5 08:07:29 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:07:29 air01a  FCP: WWN 0x500000e010772c71 reset successfully
Aug  5 08:07:30 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:07:30 air01a  FCP: WWN 0x500000e010772c71 reset successfully
Aug  5 08:12:23 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:12:23 air01a  FCP: WWN 0x500000e010717e91 reset successfully
Aug  5 08:12:24 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:12:24 air01a  FCP: WWN 0x500000e010717e91 reset successfully
Aug  5 08:12:25 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:12:25 air01a  FCP: WWN 0x500000e010717e91 reset successfully
Aug  5 08:12:26 air01a scsi: [ID 243001 kern.warning] WARNING:
/[EMAIL PROTECTED],600000/SUNW,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 (fcp0):
Aug  5 08:12:26 air01a  FCP: WWN 0x500000e010717e91 reset successfully

Here it should be noted that all these errors are only showing for the
servers having external SCSI storage but the read/write operation is
ok on the disks except one 3310 on which oracle database was
installed. I have checked sunsolve and found that it may happen for
wrong maxcontig value, but for my case I checked and confirmed that
the value is 128 which is okay for SCSI.

So, can anyone help me out by telling some more factors which can
cause this error log to be generated?

Thanks in advance.

-- 
Best Regards,
Mahfuz
_______________________________________________
Solaris-Users mailing list
[EMAIL PROTECTED]
http://www.filibeto.org/mailman/listinfo/solaris-users

Reply via email to