Run the format command.
It will see which drive failing or you might have to look for the {Unique
ID#: 081616}

Good Luck

On Jan 31, 2008 3:36 PM, Sir June <[EMAIL PROTECTED]> wrote:

> Hi,
> I got this message in my Solaris 10 box.
>
>  SUNWscsdMonitor[1826]: [ID 573593 daemon.error] [SUNWscsd
> 0x020B1E13:0x01000500 Warning] <rctrl3000> SMART Predictable Failure
> Detected(Ch:0,Id:5). Informational message. Drive may be failing.  (Primary,
> Thu Jan 31 07:38:21 2008) {Unique ID#: 081616}
>
>
> How would i know which physical disk is this? and to which filesystem it
> is mounted or which filesystem is affected?
>
> thanks,
> Sirjune
>
>
>
>
>
>  
> ____________________________________________________________________________________
> Never miss a thing.  Make Yahoo your home page.
> http://www.yahoo.com/r/hs
> _______________________________________________
> Solaris-Users mailing list
> [email protected]
> http://www.filibeto.org/mailman/listinfo/solaris-users
>
_______________________________________________
Solaris-Users mailing list
[email protected]
http://www.filibeto.org/mailman/listinfo/solaris-users