CVSROOT: /cvs
Module name: src
Changes by: [email protected] 2024/07/08 02:07:45
Modified files:
sys/arch/octeon/dev: cn30xxgmx.c
Log message:
octeon/cnmac: assume 1Gbps in the default case
avoids a division by 0 when up'ing the non-working cnmac2 on er-poe
feedback from visa@:
"The cnmac2 link is connected to a discrete Ethernet switch chip on the
PoE, and this link does not carry RGMII in-band PHY status. If the code
were to support such hardware designs in the future, something like this
patch would be needed."
this diff from miod@, same diff from visa@ in 2017
(cf https://marc.info/?l=openbsd-bugs&m=151017517115440&w=2)
ok visa@