CVSROOT: /cvs Module name: src Changes by: [email protected] 2026/09/24 02:41:41
Modified files:
usr.bin/sndiod : midi.c
Log message:
sndiod: Don't abort if a MIDI endpoint connects with non-empty buffers
When the server.thru control is set, the midi endpoints may have
non-empty buffers, which would cause the server to abort.
Found and fixed by Acts1631 <acts1631kjv at proton.me>, thanks!