CVSROOT: /cvs Module name: src Changes by: [email protected] 2016/02/10 21:02:22
Modified files:
sys/dev : ipmi.c
Log message:
ipmi(4) - Check sensor name length more carefully
Don't blindly trust sensor name info returned from BMC. Check them more
carefully. Prevent DELL R210 II from panic'ing.
Problem reported & tested by sthen@