Hi Muhammed, per default this attribute (0x12b4c) is empty. OneClick shows AlarmType (I don't remember the attributeid) in this case. That's the first line of the PCause file.
You could use this in your script: *************** ALARMTITLE=$SANM_0x12b4c [ -z "$ALARMTITLE" ] && ALARMTITLE=$(echo $PCAUSE | head -1) echo "Alarm Title: $ALARMTITLE" *************** The second line sets $ALAMTITLE to the first line of $PCAUSE if $ALAMTITLE is empty. This way you get the same as shown in OneClick in the AlarmTitle row. Regards, Marcel 2011/4/16 Muhammed Udhuman <[email protected]>: > Hi Alex, > > Please find below two methods which I used to get the Alarm Title. None of > them showing the value of the Alarm title. It returns blank. > > 1st Method: > .alarmrc > > USE_NEW_INTERFACE=true > EXTRA_ATTRS_AS_ENVVARS=0x12b4c > setscript > ALARMTITLE=$SANM_0x12b4c > echo "Alarm Title" $SANM_0X12B4C > > > 2nd Method: > .alarmrc > USE_NEW_INTERFACE=true > EXTRA_ATTRS_AS_ARGS=0x0023000e,0x11f7e,0x12b4c > > setscript > ALARMTITLE="$3" > echo "Alarm Title" $ALARMTITLE > > > Kinldy correct me if I did any mistakes in the script. > Thanks & Regards, > Muhammed Udhuman. J > > On Sat, Apr 16, 2011 at 3:50 PM, Alexander Maslobojev <[email protected]> > wrote: >> >> Hi Muhammed, >> >> please double check that your .alarmrc file has these two options >> included: >> >> ........... >> USE_NEW_INTERFACE=true >> EXTRA_ATTRS_AS_ENVVARS=0x12b4c >> ........... >> >> In the alarm script you can access this variable in this way: >> >> my $alarm_title = $ENV{SANM_0x12b4c}; # perl code >> >> Best regards, >> Alex. >> >> >> Am 16.04.2011 14:45, schrieb Muhammed Udhuman: >> >> Hi Alex, >> >> I used this attribute (0x12b4c) and nothing returned, its blank :( >> >> Regards, >> Muhammed Udhuman. J >> >> On Sat, Apr 16, 2011 at 3:08 PM, Alexander Maslobojev <[email protected]> >> wrote: >>> >>> Hello Muhammed, >>> >>> the "Alarm title" attribute ID is 0x12b4c >>> >>> Regards, >>> Alex. >>> >>> >>> From: Muhammed Udhuman [mailto:[email protected]] >>> Sent: Samstag, 16. April 2011 13:03 >>> To: spectrum >>> Subject: [spectrum] Attribute ID for Alarm Title >>> >>> >>> >>> Hi Team, >>> >>> I am using Spectrum 9.2 on win 2003. I need Alarm title in email >>> notification. $PCAUSE is giving alarm title but with symptioms, probable >>> cause and Action. >>> >>> >>> >>> Any one knows the Alarm title attribute ID, so that I can pass the >>> attribute alone and I can get only Alarm title in the email notification. >>> >>> >>> >>> Thanks & Regards, >>> >>> Muhammed Udhuman. J >>> >>> >>> >>> --To unsubscribe from spectrum, send email to [email protected] with the >>> body: unsubscribe spectrum [email protected] >> >> > > --To unsubscribe from spectrum, send email to [email protected] with the > body: unsubscribe spectrum [email protected] --- To unsubscribe from spectrum, send email to [email protected] with the body: unsubscribe spectrum [email protected]