On Apr 11, 2012, at 3:53 PM, Rob wrote: > Been staring at an issue in Spectrum for about 3 days now and think I finally > have it sorted out. > > About 2 weeks ago the Network team at my site started to configure V2 Routers > and Switches to V3 and enabling Traps to Spectrum. I suddenly got about 90 > Orange "SNMP NOT RESPONDING" alarms and bunches of Pingables in my "New > Devices" container. (I have Trap Based Discovery enabled) > …
> Now to get the Network Team to update all the duplicate engineIDs... easier > said than done... > > <BIG SIGH> > > -Rob I would also recommend to set your trap source interface so that the router/switch doesn't tag it with the IP of the egress interface. We had a few issues with duplicate engine ID's, but I think that was due to copy/past of configs. Why would you manually set the EngineID unless you really had to? Just have them remove the manual setting and the router should generate a unique new one. -Ken --- To unsubscribe from spectrum, send email to [email protected] with the body: unsubscribe spectrum [email protected]