On 10/31/07, David Brownell <[EMAIL PROTECTED]> wrote:
> On Wednesday 31 October 2007, Mike Frysinger wrote:
> > On 10/31/07, David Brownell <[EMAIL PROTECTED]> wrote:
> > > (ISTR the M25P16 in $SUBJECT has two read commands, one of
> > > which is only usable at clock rates below 33 MHz or so, but
> > > most other commands can work above that speed just fine.)
> >
> > pretty much all SPI flashes have two read commands ("slow" and "fast"
> > as they're typically called).
>
> Not DataFlash.

doesnt it ?  AT45DB642D says 0x0B is fast (up to 66mhz) while 0x03 (up to 33mhz)
-mike

-------------------------------------------------------------------------