Hi,

At 20.06 16/07/2004, Octavio Alvarez Piza wrote:

Hi, my name is Octavio and this is my first post to this list.

I'm having trouble setting Squid on an NT server. I'm using Guido
Serassio's native port. Everything worked correctly on the test machine,
but when moving to the real server (which is the PDC for the domain) I get
the following error from win32_check_group -G:

win32_check_group.exe Can't find DC for domain tecproxy-domain.

I don't know if anyone has seen this problem before. Google hasn't been of
any help for this.

Thanks.

Octavio.

This is a fixed bug in the incoming STABLE6 Windows build, that I'm expecting to release in the next week.


For now, I can send you an updated win32_check_group.exe.

Regards

Guido



-
========================================================
Guido Serassio
Acme Consulting S.r.l. - Microsoft Certified Partner
Via Gorizia, 69             10136 - Torino - ITALY
Tel. : +39.011.3249426      Fax. : +39.011.3293665
Email: [EMAIL PROTECTED]
WWW: http://www.acmeconsulting.it/



Reply via email to