for those with high volume reverse proxy (http accel) experiences....
 
 I've got 8 boxes, doing a peak of about 260 req/sec each, but they are pegged 
at 100% disk util (iostat), which I think it legitimate, given their config.   
They have two cache_dirs, each 10Gb, on two SATA disks.  cache_mem is set to 
2048, it's on a 4GB 32bit linux.  aufs.  hit ratio is around 85-90%, due to 
being URL hash balanced.  they've got about 200k objects in hot object cache, 
about 2 million objects on disk.
 
 I'm about to replace them with 6-disk 15K RPM SCSI machines, same memory 
footprint.
 What kind of performance increase can I expect, if I were to put down a 
cache_dir of 10GB on each of the six disks ?  
 
 my question is more about what can I expect from going from 2disk SATA to 
6disk SCSI.
 
 thanks

Reply via email to