Hi all,

We are using kamailio 5.1.6, configured as P-CSCF, facing following problem. 
Please refer to the attached tshark trace, too.

If during call setup (by simulated UAs) at the terminating P-CSCF the simulated 
PCRF rejects the Diameter AAR message (frame 46/47 at the attached trace), then 
the kamailio P-CSCF runs into a questionable behaviour.

By calling the Rx_AAR() function in configuration, the processing of the 200 OK 
(frame 45) is suspended (by the ims_qos module) and then resumed with the 
receipt of the AAA message (frame 47).

Now the ims_dialog module is called with the dlg_terminate("all", "reason") 
function, but the 200 OK has not yet been sent. The ims_dialog sends CANCEL 
downstream and 488 upstream. However, the 200 OK is sent additionally. We would 
rather have expected the ims_dialog module should send BYE in both directions.

When we respond the CANCEL with 481 Call/Transaction does not exist (which we 
MUST according to RFC 3261), then we would expect the ims_dialog module at 
least now to react with BYE in both directions.

Could you help? What's our misunderstanding? How could we proceed to get this 
issue fixed?

Kind regards
Christoph

____

Christoph VALENTIN
Software Developer | R&D
Core / SIP Core

P +43 50 811 3785 | M +43 664 628 3785

christoph.valen...@kapsch.net<mailto:christoph.valen...@kapsch.net>

Kapsch CarrierCom AG | Lehrbachgasse 11 | 1120 Vienna | Austria
Company Register at: Commercial Court Vienna FN 223804 z | Registered Office 
Vienna | www.kapsch.net<http://www.kapsch.net/>

[Kapsch Logo]<https://www.kapsch.net/>






The information contained in this e-mail message is privileged and confidential 
and is for the exclusive use of the addressee. The person who receives this 
message and who is not the addressee, one of his employees or an agent entitled 
to hand it over to the addressee, is informed that he may not use, disclose or 
reproduce the contents thereof, and is kindly asked to notify the sender and 
delete the e-mail immediately.

Attachment: PRM-18-2272-unsuccessful-Rx-diameter_78_filtered.pcap
Description: PRM-18-2272-unsuccessful-Rx-diameter_78_filtered.pcap

_______________________________________________
Kamailio (SER) - Users Mailing List
sr-users@lists.kamailio.org
https://lists.kamailio.org/cgi-bin/mailman/listinfo/sr-users

Reply via email to