Hi All,
After a 'few' months busy on work related projects, I can see some time coming up where I can start on the SSC (tape) module. While the code I have is something I'm not proud of, I'm after something to 'work' - proof of concept type. Once I understand what it takes to implement an SSC module, I plan on re-writing and submitting for comment and eventually inclusion into the code base. Now for my first question / hurdle.. Re: Variable block reads READ(6) When I return a "CHECK CONDITION" in response to a 'short block' read, I have not been able to figure out how to return the block of data read + the sense code with the 'Incorrect length' condition. All I seem to get back is the 'CHECK CONDITION' sense information without the block of data. No matter how long I look at the code, I haven't figured out the return path. Any pointers would be welcome.. Many thanks Mark Harvey
_______________________________________________ Stgt-devel mailing list [email protected] https://lists.berlios.de/mailman/listinfo/stgt-devel