If cylinder does not have start and end pressures assigned, attempt to
grab them from the samples instead.

Signed-off-by: Miika Turkia <[email protected]>
---
 subsurface-core/subsurface-qt/DiveObjectHelper.cpp | 10 ++++++++--
 1 file changed, 8 insertions(+), 2 deletions(-)

diff --git a/subsurface-core/subsurface-qt/DiveObjectHelper.cpp 
b/subsurface-core/subsurface-qt/DiveObjectHelper.cpp
index 9a6f318..b051389 100644
--- a/subsurface-core/subsurface-qt/DiveObjectHelper.cpp
+++ b/subsurface-core/subsurface-qt/DiveObjectHelper.cpp
@@ -38,9 +38,15 @@ static QString getPressures(struct dive *dive, enum 
returnPressureSelector ret)
        cylinder_t *cyl = &dive->cylinder[0];
        QString fmt;
        if (ret == START_PRESSURE)
-               fmt = get_pressure_string(cyl->start, true);
+               if (cyl->start.mbar)
+                       fmt = get_pressure_string(cyl->start, true);
+               else if (cyl->sample_start.mbar)
+                       fmt = get_pressure_string(cyl->sample_start, true);
        if (ret == END_PRESSURE)
-               fmt = get_pressure_string(cyl->end, true);
+               if (cyl->end.mbar)
+                       fmt = get_pressure_string(cyl->end, true);
+               else if(cyl->sample_end.mbar)
+                       fmt = get_pressure_string(cyl->sample_end, true);
        return fmt;
 }
 
-- 
2.5.0