On Tue, Jul 4, 2017 at 9:37 AM, Dirk Hohndel <d...@hohndel.org> wrote:
>
> I'm about to leave and will have limited access for the next two days.
>
> I merged Jan's initial code for OSTC support plus a fix to make it work for
> the EON Steel again. I verified that it still works on my old BT-only
> Petrel.
>
> Linus, can you check the Perdix AI with the latest master?

The EON Steel seems to work, but since it doesn't do the "force
download all dives", it's hard to tell (I have all dives from it
already). How do you usually that?

The Perdix seems to do the first command and get the first reply, but
that's it. The log doesn't look wrong, but it also doesn't seem to
download any dives (not even the first dive to test).

Hmm. Also, the Perdix didn't work at all until I used the "Paired
devices" case - trying to do it with the vendor/type just got me
rfcomm. That may be intentional.

                  Linus
_______________________________________________
subsurface mailing list
subsurface@subsurface-divelog.org
http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface

Reply via email to