> On Aug 21, 2017, at 8:50 AM, John Van Ostrand <j...@vanostrand.com> wrote:
> 
> I've been meaning to test the Cochran computers on  my android device for 
> download but I can't see it on the list of vendors in the latest app.
> 
> It uses FTDI and has the same vid (1027) and pid (24577) as some other DCs. 
> I've tried finding where it might be filtered in the code and it's not 
> apparent. 
> 
> How do I add it?

Right now this is done by adding a comment in the src/descriptor.c file in 
libdivecomputer and then running a tool that creates our lists in 
core/downloadfromdcthread.cpp:
scripts/dcTransport.pl

> Secondly, is it likely to work? All current models use two different baud 
> rates.  They use 9600 for issuing commands and for small reads but after 
> issuing a read command for dive data it switches to either 115200 (Commander) 
> or ~800,000 (EMC) to receive data. It switches back to 9600 afterwards. 

That I don't know.

/D