You would need to add a third tank. If you then have two transmitters (0 and 1):
- You “move” 0 to the “dummy” tank - 1 to the tank where it should be - 0 to the tank where it should be - delete the dummy tank From a usability perspective, this would need some improvement, but thus far it worked for me (Credits to Michael for the feature) — Attilla > On 1 Sep 2022, at 14:52, Moetaz Thabet <moetaztha...@gmail.com> wrote: > > Thanks for the tip, but I wasn't able to move them around. I have 2 tanks in > the equipment section but can't seem to drag them anywhere. What's the trick > ? > > Thanks again. > > On Thu, 1 Sept 2022, 8:05 am Attilla de Groot, <atti...@attilla.nl> wrote: > Hi Moetaz, > > > On 31 Aug 2022, at 23:11, Moetaz Thabet via subsurface > > <subsurface@subsurface-divelog.org> wrote: > > > > is there a way to switch the tank data when using a dive computer with 2 > > transmitters. > > I am using a shearwater Perdix AI - My Mac subsurface seems to be labelling > > the information from Tank 1 as tank 2 and vice versa. The same data is > > downloaded from the dive computer on my PC and is correct. > > > > Is there a way to tell subsurface which one is tank 1 and 2 ? > > Yes, that feature was recently added. You could do it in the xml file > manually, but in the equipment tab you can add the sensors column. To > actually switch you need to add another tank and you can switch them around. > > > — Attilla _______________________________________________ subsurface mailing list subsurface@subsurface-divelog.org http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface