> On 7 Sep 2022, at 10:32, Jef Driesen <j...@libdivecomputer.org> wrote:
> 
> On 5/09/2022 17:25, Attilla de Groot wrote:
>> I looked at the dive profile and the xml, but I don’t see anything that would
>> explain this. I was just diving with 100% o2 and AIR as diluent. I did have a
>> transmitter to my bailout stage that also had AIR. Could this be related?
>> I have downloaded the log through the shearwater (android) app and exported
>> it to Subsurface. A bit of a long way around, but in the end it worked. I
>> have attached those outputs, perhaps that helps in any way?
> 
> That shearwater xml file is interesting because it also contains a large 
> amount of gas mixes, and many of those contain invalid values (e.g. 02 
> percentages larger than 100%).
> 
> For example the first sample contains:
> 
>        <fractionO2>1.29</fractionO2>
>        <fractionHe>0</fractionHe>
> 
> That's a mix containing 129% 02, which of course doesn't make any sense. When 
> importing the dive into shearwater cloud desktop, I also get those many gas 
> switches and the invalid values. See the attached screenshot.
> 
> Except for those fractionO2 values, the rest of the data looks normal. So at 
> first sight the problem appears to be in the raw data, and not the parsing. 
> Maybe a bug in the Petrel firmware? I'll report the problem to shearwater.
> 
> The UDDF export doesn't seem to contain any gas mix info at all, and when 
> importing the shearwater xml into subsurface, the gas mix info seems to be 
> ignored too. So that's probably why your workaround is working.

Thank you for looking into this, much appreciated. I’m curious how shearwater 
will respond.

I have planned another CCR dive tomorrow. I’ll provide the same data again for 
that dive.


— Attilla