Hi Jef, I have a question re the Divesoft Liberty CCR. From their website I understand it has a total of four (2x2) O2 sensors rather than the three other rebreathers have. We now had a user reporting Subsurface to crash when handling a dive from that computer and looking at the subsurface source there is indeed an assert that makes sure there are no more than three sensors. Obviously that is not correct (but leave aside for a moment the question how a voting logic actually is supposed to work with four sensors).
Looking at libdivecomputer/src/divesoft_freedom_parser.c it seems, that correctly reports the number of sensors to be 4 but when actually reporting data from the sensors it reports the data from all sensors as if it were only one. Or am I misreading the code? Does the computer actually report which sensors are voted out? Is there a way for subsurface to assign the values to the individual sensors? Best Robert