Hi Jef,

I have a question re the Divesoft Liberty CCR. From their website I understand 
it has a total of four (2x2) O2 sensors rather than the three other rebreathers 
have. We now had a user reporting Subsurface to crash when handling a dive from 
that computer and looking at the subsurface source there is indeed an assert 
that makes sure there are no more than three sensors. Obviously that is not 
correct (but leave aside for a moment the question how a voting logic actually 
is supposed to work with four sensors).

Looking at libdivecomputer/src/divesoft_freedom_parser.c it seems, that 
correctly reports the number of sensors to be 4 but when actually reporting 
data from the sensors it reports the data from all sensors as if it were only 
one. Or am I misreading the code? Does the computer actually report which 
sensors are voted out? Is there a way for subsurface to assign the values to 
the individual sensors?

Best
Robert

Attachment: signature.asc
Description: Message signed with OpenPGP

_______________________________________________