In the current implementation, detectors for actuation are only used if all
traffic from the detector lane gets the unconditional green light ('G') in
a particular phase.
Otherwise it could cause useless phase extensions when the first vehicle on
a given lane is not allowed to drive.
In your signal plan all lanes have a mixture of green/red connections are a
conditional green light ('g') and thus actuation is disabled.

regards,
Jakob

Am Mo., 11. Nov. 2019 um 06:11 Uhr schrieb Thilagavathy Giri <
[email protected]>:

> hello sir,
>  with this i have attached my net.xml file.thanks for your support.
>
> with thanks
> M S Thilagavathy
> Research scholar ,
>
>
> On Sun, Nov 10, 2019 at 7:44 PM Jakob Erdmann <[email protected]>
> wrote:
>
>> The warnings "has no controlling detector" indicate that actuation is not
>> active at that intersection. This would also be the reason why different
>> parameters do not affect the outputs.
>> The most likely reason for that warning are unprotected left turns
>> without dedicated turning lanes. Please post a network that contains just
>> the intersection controlled by traffic light n2.
>>
>> Am Fr., 8. Nov. 2019 um 02:22 Uhr schrieb Thilagavathy Giri <
>> [email protected]>:
>>
>>> hi all,
>>> i tried with gap-based actuated traffic control .  i want to know
>>> whether  the Max-gap value will affect the summary or trip output.  for a
>>> four leg straight cross intersection,   flow is set to 500v/hr.  i changed
>>> max-gap value to 2, 4, 5, 9. but there is no difference in summary or trip
>>> output. is it possible to get a difference.?
>>>    my another query is
>>> when simulating with default actuated phase plan there is no warning.
>>> default phase plan is
>>> <tlLogic id="n2" type="actuated" programID="0" offset="0">
>>> <param key="max-gap" value="3.0"/>
>>>   <param key="detector-gap" value="2.0"/>
>>>   <param key="show-detectors" value="true"/>
>>>   <param key="file" value="NULL"/>
>>>   <param key="freq" value="300"/>
>>>         <phase duration="39" state="GggrrrGggrrr" minDur="15"
>>> maxDur="50"/>
>>>         <phase duration="6"  state="yyyrrryyyrrr"/>
>>>         <phase duration="39" state="rrrGggrrrGgg" minDur="15"
>>> maxDur="50"/>
>>>         <phase duration="6"  state="rrryyyrrryyy"/>
>>>     </tlLogic>
>>>
>>> if i change this phase plan  as below
>>>
>>>
>>> <additional>
>>> <tlLogic id="n2" type="actuated" programID="1" offset="0">
>>> <param key="max-gap" value="9.0"/>
>>>   <param key="detector-gap" value="2.0"/>
>>>   <param key="show-detectors" value="true"/>
>>>   <param key="file" value="NULL"/>
>>>   <param key="freq" value="300"/>
>>>         <phase duration="45" state="rgrGrgrgrGrg" minDur="15"
>>> maxDur="50"/>
>>>         <phase duration="5"  state="ryryryryryry"/>
>>>         <phase duration="35" state="GrgrgrGrgrgr" minDur="15"
>>> maxDur="50"/>
>>>         <phase duration="5"  state="yryryryryryr"/>
>>>     </tlLogic>
>>> </additional>
>>> i get some warning
>>>
>>> Loading configuration... done.
>>> Loading net-file from 'E:\thilaga\sumo_demo\thiactuated.net.xml'... done
>>> (10ms).
>>> Loading additional-files from 'E:\thilaga\sumo_demo\passdist.add.xml'...
>>> done (26ms).
>>> Loading additional-files from
>>> 'E:\thilaga\sumo_demo\optacttls.add.xml'...
>>>
>>>
>>>
>>>
>>>
>>>
>>> *Warning: At actuated tlLogic 'n2', actuated phase 0 has no controlling
>>> detectorWarning: At actuated tlLogic 'n2', actuated phase 2 has no
>>> controlling detectorWarning: At actuated tlLogic 'n2', linkIndex 0 has no
>>> controlling detectorWarning: At actuated tlLogic 'n2', linkIndex 3 has no
>>> controlling detectorWarning: At actuated tlLogic 'n2', linkIndex 6 has no
>>> controlling detectorWarning: At actuated tlLogic 'n2', linkIndex 9 has no
>>> controlling detectordone (2*ms).
>>> Loading additional-files from 'E:\thilaga\sumo_demo\laacdum.add.xml'...
>>> done (1ms).
>>> Loading done.
>>> Simulation started with time: 0.00
>>> Warning: Vehicle '7.0' performs emergency braking with decel=-9.00
>>> wished=4.50 severity=1.00, time=41.00.
>>> Simulation ended at time: 7897.00
>>>
>>>  is it ok to proceed or we need to rectify it.  how to rectify .
>>>
>>>
>>> with thanks and regards
>>> M S Thilagavathy
>>> _______________________________________________
>>> sumo-user mailing list
>>> [email protected]
>>> To change your delivery options, retrieve your password, or unsubscribe
>>> from this list, visit
>>> https://www.eclipse.org/mailman/listinfo/sumo-user
>>>
>> _______________________________________________
>> sumo-user mailing list
>> [email protected]
>> To change your delivery options, retrieve your password, or unsubscribe
>> from this list, visit
>> https://www.eclipse.org/mailman/listinfo/sumo-user
>>
> _______________________________________________
> sumo-user mailing list
> [email protected]
> To change your delivery options, retrieve your password, or unsubscribe
> from this list, visit
> https://www.eclipse.org/mailman/listinfo/sumo-user
>
_______________________________________________
sumo-user mailing list
[email protected]
To change your delivery options, retrieve your password, or unsubscribe from 
this list, visit
https://www.eclipse.org/mailman/listinfo/sumo-user

Reply via email to